English
Language : 

FNB40560_15 Datasheet, PDF (11/16 Pages) Fairchild Semiconductor – Motion SPMR 45 Series
Time Charts of Protective Function
Input Signal
Protection
Circuit State
Control
Supply Voltage
RESET
SET
UVCCR
a1
UVCCD
a3
a2
a4
RESET
a6
a7
Output Current
a5
Fault Output Signal
a1 : Control supply voltage rises: after the voltage rises UVCCR, the circuits start to operate when next input is applied.
a2 : Normal operation: IGBT ON and carrying current.
a3 : Under-voltage detection (UVCCD).
a4 : IGBT OFF in spite of control input condition.
a5 : Fault output operation starts.
a6 : Under-voltage reset (UVCCR).
a7 : Normal operation: IGBT ON and carrying current.
Figure 11. Under-Voltage Protection (Low-Side)
Input Signal
Protection
Circuit State
Control
Supply Voltage
RESET
UVBSR
b1
UVBSD
b2
SET
b3
b4
RESET
b5
b6
Output Current
High-level (no fault output)
Fault Output Signal
b1 : Control supply voltage rises: after the voltage reaches UVBSR, the circuits start to operate when next input is applied.
b2 : Normal operation: IGBT ON and carrying current.
b3 : Under-voltage detection (UVBSD).
b4 : IGBT OFF in spite of control input condition, but there is no fault output signal.
b5 : Under-voltage reset (UVBSR).
b6 : Normal operation: IGBT ON and carrying current.
Figure 12. Under-Voltage Protection (High-Side)
©2011 Fairchild Semiconductor Corporation
11
Motion SPM® 45 Series Rev. C4
www.fairchildsemi.com