Function
Range
Accuracy % rdg + digits
Resolution
Input Protection
Comments
Capacitance 2,20,200nF
±(2.5% + 3 digits)
1,10,100pF
Test Freq: 400Hz
(MV-120)
2,20µF
1nF, 10nF
Test V: 40mV
Capacitance 2,20,200nF
±(2.5% + 10 digits)
0.1,1,10,100pF
(MV-130)
2,20µF
1nF
Temperature
(MV-120)
-18 to 4000C
0 to7520F
±(0.75% + 4 digits)
1oC/F
Type K Thermocouple
-40 to 10000C
±(1.6% + 15 digits)
-40 to 18320F
Frequency
20kHz
±(1.5% + 10 digits)
1Hz
250VAC/VDC
Sensitivity: 100mV
(MV-130)
Diode test
Forward DC current approx. 1mA, Reverse DC voltage approx. 3V
Transistor hFE 0 to 1000
Base current approx. 10uA, Vce approx 2.8V
Continuity
Buzzer sounds when R < 30Ω
Battery check 1.5V
30Ω Internal resistance
(MV-110)
9.0V
1.8kΩ Internal resistance
Square Wave
Approx. 50Hz, 4-6V
(MV-110)
Note: Accuracy is specified for a period of one year after calibration and at 18 oC to 28 oC (64 oF to 82 oF) RH: 75% max.