Specifications
General Specifications
Display
Polarity
Jaw opening
Current sensor
AC Current Bandwidth
AC Voltage Bandwidth
Overload indication
Display rate
Battery
Low Battery indication
Auto Power off
Operating conditions
Storage conditions
Altitude
Weight
Dimensions
Standards
2000 count Digit LCD with white LED backlight
Minus sign (-) indicates negative polarity
0.7” (18mm)
Hall effect sensor type
50/60Hz
50/400Hz
“OL” displayed on the LCD
2 readings/second, nominal
Two 1.5V AAA batteries
“BATT” displayed on the LCD
approx. 15 minutes
32 to 86ºF (0 to 30ºC) 90%RH; 86 to 104ºF (30 to 40ºC) 75%RH;
104 to 122ºF (40 to 50ºC) 45%RH
- 14 to 140ºF (-30 to 60ºC); < 90% Relative Humidity
Operate at less than 3000 meters
6.2 oz. (176g) including battery
6.5 x 2.6 x 1.3” (164 x 65 x 32mm) (HWD)
For indoor use and in accordance with the requirements for
double insulation to IEC1010-1 (1995): EN61010-1 (1995)
Overvoltage Category III 300V and Category II 600V, Pollution
CC Degree 2.
5
MA150 Ver. 2.0 08/07