English
Language : 

EX710 Datasheet, PDF (5/12 Pages) Extech Instruments Corporation. – 800 Amp Clamp Meters
Specifications
Function
Range &
Resolution
AC Current
50/60 Hz
True RMS on
EX720 & EX730
40.00A AC
400.0A AC
800A AC
DC Current 40.00A DC
EX730 only
400.0A DC
800A DC
400.0mV AC
AC Voltage
50/60Hz
True RMS on
EX720 & EX730
4.000V AC
40.00V AC
400.0V AC
600V AC
400.0mV DC
4.000V DC
DC Voltage 40.00V DC
400.0V DC
600V DC
400.0Ω
EX710
Accuracy
(% of reading + digits)
EX720
EX730
± (2.8% + 10d)
± (2.5% + 10d)
± (5% + 10d)
± (2.8% + 8d)
± (2.5% + 8d)
± (5% + 10d)
± (3.0% + 8d)
± (2.8% + 5d)
± (2.8% + 10d)
± (5% + 10d)
NA
NA
± (5% + 10d)
± (2.8% + 10d)
± (1.5% + 10d)
± (1.0% + 10d)
± (1.0% + 10d)
± (1.8% + 8d)
± (1.5% + 5d)
± (1.5% + 5d)
± (2.5% + 8d)
± (0.8% + 2d)
± (2.0% + 5d)
± (0.8% + 2d)
± (2.0% + 5d)
± (0.8% + 2d)
± (1.5% + 2d)
± (1.5% + 2d)
± (1.5% + 2d)
± (2.0% + 2d)
± (1.0% + 4d)
± (2.0% + 2d)
± (1.0% + 4d)
± (2.0% + 2d)
± (1.0% + 4d)
4.000kΩ
40.00kΩ
Resistance
400.0kΩ
± (1.5% + 2d)
± (1.5% + 2d)
± (1.5% + 2d)
4.000MΩ
± (2.5% + 3d)
± (2.5% + 3d)
± (2.5% + 3d)
40.00MΩ
± (3.5% + 5d)
± (3.5% + 5d)
± (3.5% + 5d)
4.000nF
± (5.0% + 30d)
± (5.0% + 30d)
± (5.0% + 30d)
40.00nF
± (5.0% + 20d)
± (5.0% + 20d)
± (5.0% + 20d)
400.0nF
4.000µF
Capacitance
40.00µF
± (3.0% + 5d)
± (3.0% + 5d)
± (3.0% + 5d)
400.0µF
± (4.0% + 10d)
± (4.0% + 10d)
± (4.0% + 10d)
4.000mF
± (10% + 10d)
± (10% + 10d)
± (10% + 10d)
40.00mF
unspecified
unspecified
unspecified
4.000kHz
± (1.5% + 2d)
± (1.5% + 2d)
± (1.5% + 2d)
Frequency
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401 to 4000Hz)
5
EX700 Series Version 3.0 1/05