English
Language : 

MA220 Datasheet, PDF (3/9 Pages) Extech Instruments Corporation. – 400A AC/DC Clamp Meter
Specifications
Function
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Capacitance
Frequency
Duty Cycle
Temperature
Range
Accuracy (of
reading)
40.00 ADC
0-20.00 ADC
± (2.5% + 6 digits)
400.0 ADC
20.00-40.00 ADC
0-300.0 ADC
± (3% + 6 digits)
± (2.5% + 6 digits)
300.0-400.0 ADC
± (3.5% + 6 digits)
40.00 AAC
0-20.00 AAC
± (3% + 10 digits)
20.00-40.00 AAC
± (5% + 10 digits)
400.0 AAC
0-300.0 AAC
± (3% + 10 digits)
300.0-400.0 AAC
± (5% + 10 digits)
400.0mV
± (0.8% + 3 digits)
4.000V
40.00V
± (1.5% + 3 digits)
400.0V
600V
± (2.0% + 3 digits)
400.0mV
± (1% + 10 digits)
4.000V
40.00V
± (2% + 5 digits)
400.0V
600V
± (2% + 5 digits)
400.0Ω
± (1.0% + 4 digits)
4.000kΩ
40.00kΩ
± (1.5% + 2 digits)
400.0kΩ
4.000 MΩ
± (2.5% + 3 digits)
40.00MΩ
± (3.5% + 5 digits)
40.00nF
± (5% + 30 digits)
400.0nF
± (3% + 5 digits)
4.000µF
± (3.5% + 5 digits)
40.00µF
100.0µF
± (5% + 5 digits)
5.000Hz
± (1.5% + 5 digits)
50.00Hz
500.0Hz
± (1.2% + 2 digits)
Sensitivity: 5~5KHz:
5.000KHz
50.00KHz
150.0KHz
10Vrms min.
5KHz~150KHz:
40Vrms min.
0.5% to 99.0%
± (1.2% + 2 digits)
Pulse Width: 100µs-100ms, Frequency: 5Hz to 150KHz
-50.0 to 400.0°C
-50.0 to -20.0°C
± 7°C
400 to 1000°C
-58.0 to 400.0°F
-20.0 to 400.0°C
400 to 1000°C
-58.0 to 0°F
± (3% + 5 °C)
± 14°F
400 to 1832°F
0 to 400.0°F
400 to 1832°F
± (2.5% + 6 digits)
± (3% + 7°F)
3
MA220 V1.3 10/06