English
Language : 

MN36 Datasheet, PDF (1/2 Pages) Extech Instruments Corporation. – Auto-Ranging Mini MultiMeter
Safety
This symbol, adjacent to another symbol or terminal, indicates
the user must refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under
normal use, hazardous voltages may be present
Double insulation
1. Improper use of this meter can cause damage, shock, injury or death.
Read and understand this user manual before operating the meter.
2. Make sure any covers or battery doors are properly closed and ured.
3. Always remove the test leads before replacing the battery or fuses.
4. Inspect the condition of the test leads and the meter itself for any
damage before operating the meter. Repair any damage before use.
5. Do not exceed the maximum rated input limits.
6. Use great care when making measurements if the voltages are
greater than 25VAC rms or 35VDC. These voltages are considered a
shock hazard.
7. Always discharge capacitors and remove power from the device
under test before performing Diode, Resistance or Continuity tests.
8. Remove the battery from the meter if the meter is to be stored for
long periods.
9. To avoid electric shock, do not measure AC current on any circuit
whose voltage exceeds 250V AC.
Input Limits
Function
Maximum Input
VDC, VAC
600V AC/600V AC
Resistance, Diode, Continuity
500V DC/AC
mA DC
200mA DC
10A DC
10A DC (15 seconds max.
every 15 min.)
Frequency
250V DC/AC
Warranty
EXTECH INSTRUMENTS CORPORATION warrants this instrument to
be free of defects in parts and workmanship for one year from date of
shipment (a six month limited warranty applies on sensors and cables).
If it should become necessary to return the instrument for service during
or beyond the warranty period, contact the Customer Service
Department at (781) 890-7440 ext. 210 for authorization or visit our
website at www.extech.com for contact information. A Return
Authorization (RA) number must be issued before any product is
returned to Extech. The sender is responsible for shipping charges,
freight, insurance and proper packaging to prevent damage in transit.
This warranty does not apply to defects resulting from action of the user
such as misuse, improper wiring, operation outside of specification,
improper maintenance or repair, or unauthorized modification. Extech
specifically disclaims any implied warranties or merchantability or fitness
for a specific purpose and will not be liable for any direct, indirect,
incidental or consequential damages. Extech's total liability is limited to
repair or replacement of the product. The warranty set forth above is
inclusive and no other warranty, whether written or oral, is expressed or
implied.
User’s Manual
MiniTecTM Series
Model MN36
Auto-Ranging Mini MultiMeter
3999
Introduction
Congratulations on your purchase of Extech’s MN36 Auto-Ranging
Multimeter. This meter measures AC/DC Voltage, AC/DC Current,
Resistance, Capacitance, Frequency, Temperature, Diode Test and
Continuity. Proper use and care of this meter will provide many years of
reliable service.
Specifications
Accuracy
Stated at 73oF ±10oF (23oC ±5 oC) and less than
70% RH
Diode Test
Test current of 0.6mA maximum, open circuit
voltage 1.5V DC typical
Continuity Check Audible signal will sound if the resistance is less
than approximately <8Ω
Temperature sensor Requires type K thermocouple
Input Impedance 10MΩ (V AC/DC)
Display
3999 count LCD
Overrange
“OL” is displayed
Polarity
Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity.
Measurement Rate 3 times per second, nominal
Low Battery
“ ” is displayed if battery voltage drops below
operating voltage
Batteries
Requires (2) AAA batteries
Fuses
mA range; 250mA/250V fast blow
Operating Temp
Storage Temp
10A range, no protection
32oF to 104oF (0oC to 40oC)
-4oF to 140oF (-20oC to 60oC)
Relative Humidity Maximum relative humidity 80% for temperatures
up to 31°C decreasing linearly to 50% relative
humidity at 40°C.
Operating Altitude 7000ft (2000 meters) maximum
Weight
5.4 oz. (153g).
Size
5.43” x 2.83” x 1.5” (138mm x 72mm x 38mm)
Safety
For indoor use and in accordance with
Overvoltage Category II, Pollution Degree 2.
Category II includes local level, appliance,
portable equipment, etc., with transient
overvoltages less than Overvoltage Category III
Specifications
Function
DC Voltage
(V DC)
AC Voltage
(V AC)
DC Current
AC Current
(40 to 400Hz)
Range
400.0mV
4.000V
40.00V
400.0V
600V
4.000V
40.00V
400.0V
600V
400.0µA
4000µA
40.00mA
200.0mA
10A
400.0µA
4000µA
40.00mA
200.0mA
10A
Accuracy
±(0.5% reading + 4 digits)
±(0.8% reading + 4 digits)
50-60Hz
±(0.8% rdg + 4 d)
40-400Hz
±(2% rdg + 5 d)
±(1.2% rdg + 5 d)
±(1.2% reading + 4 digits)
±(2.5% reading + 4 digits)
±(1.5% reading + 5 digits)
±(3% reading + 5 digits)
Resistance
Capacitance
Frequency
Temp °F
Temp °C
400.0Ω
4.000kΩ
40.00kΩ ±(1.2% reading + 4 digits)
400.0kΩ
4.000MΩ
20.00MΩ ±(3.0% reading + 5 digits)
4.000nF Not specified
40.00nF
400.0nF ±(3.0% reading + 10 digits)
4.000µF
40.00µF Not Specified
100µF
10.00Hz
100Hz
1.000kHz
±(1.0% reading + 4 digits)
10Hz to 1MHz
10.00kHz
100.0kHz
Sensitivity: 5.0Vrms
1.000MHz
5.000MHz Not specified
-40 to
1400°F
-40 to 650°F; ±(1.0% rdg + 10 digits)
651 to 1400°F; ±(3% rdg + 10 digits)
-20 to 400°C; ±(1.0% rdg + 10 digits)
-20 to 750°C 400 to 750°C; ±(3% rdg + 10 digits)
(probe accuracy not included)