English
Language : 

XRT5894 Datasheet, PDF (7/19 Pages) Exar Corporation – Four-Channel E1 Line Interface (3.3V or 5.0V)
XRT5894
ELECTRICAL CHARACTERISTICS (CONT’D)
Test Conditions: VCC = 3.3V or 5.0V + 5%, TA = -40 to 25 to 85°C, Unless Otherwise Specified
Symbol Parameter
Power Specifications VCC =5.0V (Cont’d)
PC
Power Consumption 120W
PC
Power Consumption 75W
PC
Power Consumption 120W
AC Electrical Characteristics
VTXOUT
VTXOUT
TXPW
PNIMP
T1
T2
TSU
Output Pulse Amplitude
(RL = 75W)
Output Pulse Amplitude
(RL = 120W)
Output Pulse Width
Pos/Neg Pulse Unbalanced
TXCLK Clock Period (E1)
TXCLK Duty Cycle
Data Set-up Time, TDATA to
TXCLK
THO
Data Hold Time, TDATA to
TXCLK
TR
TF
T3-noclk
TXCLK Rise Time (10% to 90%)
TXCLK Fall Time (10% to 90%)
Data Prop. Delay No-Clock
Mode
T3-clk
T4
T5
T6
T7
Data Prop. Delay Clock Mode
Receive Data High
RX Data Prop. Delay
Receive Rise Time
Receive Rise Time
Min.
2.13
2.70
224
30
75
30
219
Typ.
1075
1025
940
2.37
3.0
244
5
488
50
40
40
35
470
244
Max.
1345
1300
1220
2.60
3.30
264
70
50
269
40
40
40
Unit Conditions
mW All 1’s Transmit and Receive
mW 50% data density, Transmit and Re-
ceive
mW 50% data density, Transmit and Re-
ceive
V
Trans. = 1:2 ratio, 9.1W in series
with each end of primary
V
Trans. = 1:2 ratio, 9.1W in series
with each end of primary
ns
%
ns
%
ns 50% TXCLK Duty Cycle
ns 50% TXCLK Duty Cycle
ns
ns
ns
ns 50% TXCLK Duty Cycle
ns 0dB Cable Loss
ns 15pF Load
ns 15pF Load
ns 15pF Load
Note:
Bold face parameters are covered by production test and guaranteed over operating temperature range.
ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . -65°C to +150°C
Operating Temperature . . . . . . . . . . -40°C to +85°C
Supply Voltage . . . . . . . . . . . . . . . . . . . -0.3V to +6.0V
ESD Protection . . . . . . . . . . . . . . . . . . >1000V (HBM)
Rev. 1.10
7