English
Language : 

XR8038 Datasheet, PDF (5/16 Pages) Exar Corporation – Precision Waveform Generator
XR-8038A
DC ELECTRICAL CHARACTERISTICS (CONT’D)
Test Conditions: VS = +5V to +15V, TA = 25°C, RL = 1MW, RA = RB = 10kW, C1 = 3300pF, S1 closed, unless
otherwise specified. (See Figure 2.)
Parameter
Output Characteristics (Cont’d)
Output Impedance
Sine-Wave Amplitude
(Peak-to-Peak)
Distortion
Unadjusted
Adjusted
Min.
0.2
Typ.
200
0.22
0.8
0.5
0.3
Max.
Unit Conditions
W
x VSPLY
IOUT = 5mA
RL = 100kW
3
%
RL = 1MW4,5
%
RL = 1MW4,5
%
Notes
4 Triangle duty cycle set at 50%, use RA and RB.
5 As RL is decreased distortion will increase, RL min [ 50KW.
Bold face parameters are covered by production test and guaranteed over operating temperature range.
Specifications are subject to change without notice
ABSOLUTE MAXIMUM RATINGS
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36V
Power Dissipation (package limitation)
Plastic Package . . . . . . . . . . . . . . . . . . 625mW
Derate Above +25°C . . . . . . . . . . . . . 5mW/°C
Storage Temperature Range . . . . . . -65°C to +150°C
Rev. 2.01
5