TMIN to TMAX and VCC = 5V +/-5% unless otherwise noted.
PARAMETERS
MIN.
POWER REQUIREMENTS
Supply Voltage VCC
Supply Current
+4.75
SP485
TYP.
900
900
SP483
600
600
SP483
ENVIRONMENTAL AND MECHANICAL
Operating Temperature
Commercial (_C_)
0
Industrial (_E_)
-40
Storage Temperature
-65
Package: Plastic DIP (_P), NSOIC (_N)
ELECTRICAL CHARACTERISTICS
MAX. UNITS CONDITIONS
+5.25 Volts
µA No Load; RE, DI = 0V or VCC;
DE = VCC
µA No Load; RE = 0V, DI = 0V or 5V;
DE = 0V
µA No Load; RE, DI = 0V or VCC;
DE = VCC
µA No Load; RE = 0V, DI = 0V or 5V;
DE = 0V
10
µA Shutdown Mode; DE = 0V, RE = VCC
70
ºC
+85
ºC
+150
ºC
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com

SP483_485_101_062711