SP3508EB Datasheet, PDF (5/36 Pages) Sipex Corporation – Evaluation Board Manual | |||
|
◁ |
ELECTRICAL SPECIFICATIONS
TA = 0 to 70°C and VCC = 3.3V ± 5% unless otherwise noted. The ⦠denotes the specifications which apply over the full operating tempera-
ture range (-40°C to +85°C), unless otherwise specified.
PARAMETER
MIN. TYP. MAX.
UNITS
CONDITIONS
V.35 DRIVER DC Parameters (Outputs)
Open Circuit Voltage
Test Terminated Voltage
+/-0.44
Offset
Output Overshoot
-0.2VST
Source Impedance
50
Short-Circuit Impedance
135
V.35 DRIVER AC Parameters (Outputs)
Transition Time
Propagation Delay: tPHL
30
Propagation Delay: tPLH
30
Differential Skew
Max. Transmission Rate
20
V.35 RECEIVER DC Parameters (Inputs)
Sensitivity
+/-50
Source Impedance
90
Short-Circuit Impedance
135
V.35 RECEIVER AC Parameters
Propagation Delay: tPHL
30
Propagation Delay: tPLH
30
Skew
5
Max. Transmission Rate
20
TRANSCEIVER LEAKAGE CURRENTS
Driver Output 3-State Cur-
rent
Receiver Output 3-State
1
Current
+/-1.20
+/-0.66
+/-0.6 â¦
+0.2VST â¦
150 â¦
165
20
â¦
85
â¦
85
â¦
5
â¦
â¦
+/-200 â¦
110
165
85
85
10
200
10
V
V
V
V
â¦
â¦
ns
ns
ns
ns
Mbps
Per Figure 16
Per Figure 25
Per Figure 25
Per Figure 25; VST = Steady State
value
Per Figure 26; ZS = V2/V1 x 50
Per Figure 27
VCC = 3.3V for AC parameters
Per Figures 32 and 35; CL = 20pF
Per Figures 32 and 35; CL = 20pF
Per Figures 32 and 35; CL = 20pF
mV
â¦
â¦
ns
ns
ns
Mbps
Per Figure 29; ZS = V2/V1 x 50â¦
Per Figure 30
VCC = 3.3V for AC parameters
Per Figures 32 and 37; CL = 20pF
Per Figures 32 and 37; CL = 20pF
Per Figure 32; CL = 20pF
µA Per Figure 31; Drivers Disabled
µA DX = 111
Exar Corporation 48720 Kato Road, Fremont CA, 94538 ⢠(510)668-7017 ⢠www.exar.com
SP3508_100_072208
|
▷ |