English
Language : 

XRT6164A_07 Datasheet, PDF (4/10 Pages) Exar Corporation – Digital Line Interface Transceiver
XRT6164A
ELECTRICAL CHARACTERISTICS
Test Conditions: V CC = 5V +/- 5%, T A = 25°C, Unless Otherwise Specified
Parameters
Min. Typ. Max. Units Conditions
DC Electrical Characteristics
Supply Voltage
4.75 5 5.25 V
Analog Supply Current
7
10 mA
Digital Supply Current
17 22 mA
Receiver
Input Signal
1
2.2 V p Measured from Pins 1 or 16 with Respect to Pin 2
Dynamic Range
1 0 d B Maximum Cable Loss Range
Input Impedance
20
kΩ Measured Between Pins 1 and 16
Input Slicing Threshold
50
% Percent of Peak Input Signal Amplitude
Input Bias Voltage
1.45
V Measured at Pin 2
Loss of Signal Alarm Threshold
150
mVp Measured from Pins 1 or 16 with Respect to Pin 2
Loss of Signal Alarm Level
1.5
d B Difference Between Alarm-on and Alarm-off
Hysteresis
Levels
Peak Detector Leakage
-80
μA
Data Output Low
Data Output High
Alarm Output Low
Alarm Output High
3.0
V CC -
0.5
0.4 V Measured at Pins 5 or 12, I OUT = +1.6mA
V Measured at Pins 5 or 12, I OUT = -40μA
0.4 V Measured at Pin 3; I OUT = +1.6mA
V Measured at Pin 3; I OUT = -40μA
TCM Input Low Voltage
0.8 V Measured at Pin 15; I IN Min = -500μA, I IN Max =
+5μA
Transmitter
Input Low Voltage
Input High Voltage
Output Low Voltage
Output Low Current
Output Leakage Current
2.2
-100
0.8 V Measured at Pins 6, 11; I IN = -700μA
V Measured at Pins 6, 11; I IN = +5μA
1.2 V Measured at Pins 8, 10; I OUT = -40mA
4 0 mA Measured at Pins 8, 10; V OUT = 1V
μA Measured at Pins 8, 10; V OUT = 10V Outputs in
off state
AC Electrical Characteristics
Receiver
Input Level
1
2.2 V p Pin 1, 16 with Respect to Pin 2 1
Output Rise Time
80 n s Pins 5, 12; C L = 15pF, 10% to 90%
Output Fall Time
8 0 n s Pins 5, 12; C L =15pF, 90% to 10%
Notes:
1. Higher input voltages are possible if a resistive input attenuator is used.
Bold face parameters are covered by production test and guaranteed over operating temperature range.
Rev. 3.0.0
4