English
Language : 

SP3070E Datasheet, PDF (4/20 Pages) Exar Corporation – ±15kV ESD-Protected, 3.3V, 1/8 Load, Failsafe RS-485/RS422 Transceivers
ELECTRICAL CHARACTERISTICS
Unless otherwise noted VCC = +3.3 ±0.3V, ambient temperature TMIN < TA < TMAX. Typical values are at VCC = 3.3,
ambient temperature TA = +25ºC. The ♦ denotes the specifications which apply over the full operating range un-
less otherwise noted.
PARAMETERS
SYM MIN TYP MAX UNITS ♦
CONDITIONS
Input Current (A and B)
Half Duplex
Thermal-Shutdown Threshold
Thermal Shutdown Hysteresis
RECEIVER
Receiver Differential Threshold
(Sensitivity)
Receiver Input Hysteresis
RO Output High Voltage
RO Output Low Voltage
Tri-State Output Current at
Receiver
Receiver Input Resistance
Receiver Output Short-Circuit
Current
SUPPLY CURRENT
IA,B
-100
125
µA
♦
DE = GND
VCC = GND or 3.6
VIN = +12V
VIN = -7V
TTS
165
ºC ♦
TTSH
15
ºC ♦
VTH -200 -125 -50
mV
- 7 V ≤ VCM ≤ 1 2 V
∆ V TH
15
VOH
Vcc -
0.6
VOL
0.4
mV ♦ Va + Vb = 0V
V
♦ IO = -1mA
V
♦ IO = 1mA
IOZR
+/-1
µA
♦ 0 ≤ V O ≤ V CC
RIN
96
kΩ
♦ -7V ≤VCM ≤ 1 2 V
IOZR
±60 mA
0 V ≤ V RO ≤ V CC
Supply Current
ICC
Supply Current in Shutdown
mode
ISHDN
ESD PROTECTION
0.8 1.5
0.8 1.5
0.8 1.5
0.05 3
No Load, RE = 0, DE = VCC
mA
♦ No Load, RE = VCC , DE = VCC
No Load, RE = 0, DE = 0
µA
RE = VCC , DE = GND
±15
ESD Protection for Y, Z, A, and B
±15
Human Body Model
kV ♦ Air Gap (IEC 1000-4-2)
±8
Contact (IEC 1000-4-2)
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
4
SP3070E-SP3078E_100_061109