English
Language : 

XRT83SL38 Datasheet, PDF (37/89 Pages) Exar Corporation – OCTAL T1/E1/J1 SH TRANSCEIVER WITH CLOCK RECOVERY AND JITTER ATTENUATOR
XRT83SL38
OCTAL T1/E1/J1 SH TRANSCEIVER WITH CLOCK RECOVERY AND JITTER ATTENUATOR
PRELIMINARY
REV. P1.1.0
diagram for T1 (100Ω) in the external termination mode. Figure 13 is a simplified block diagram for E1 (75Ω) in
the external termination mode.
TABLE 10: TRANSMIT TERMINATION CONTROL
TRATIO
0
1
TURNS RATIO
1:2.45
1:2
Table 11 summarizes the transmit terminations.
TERSEL1
TABLE 11: TRANSMIT TERMINATIONS
TERSEL0 TXTSEL TRATIO
Rint Ω
0=EXTERNAL
1=INTERNAL
SET BY
CONTROL
BITS
n
Rext Ω
Cext
n, Rext, AND Cext ARE SUGGESTED
SETTINGS
0
T1
100 Ω
0
0
0
0
0
0Ω
2.45
3.1Ω
0
0
0
1
0Ω
2
3.1Ω
0
0
1
x
12.5Ω
2
0Ω
0.68µF
0
J1
0
110 Ω
0
1
0
0
0Ω
2.45
3.1Ω
0
1
0
1
0Ω
2
3.1Ω
0
1
1
x
13.75Ω
2
0Ω
0.68µF
1
E1
1
75 Ω
1
0
0
0
0Ω
2.45
6.2Ω
0
0
0
1
0Ω
2
9.1Ω
0
0
1
x
9.4Ω
2
0Ω
0.68µF
1
E1
1
120 Ω
1
1
0
0
0Ω
2.45
6.2Ω
0
1
0
1
0Ω
2
9.1Ω
0
1
1
x
15Ω
2
0Ω
0.68µF
REDUNDANCY APPLICATIONS
Telecommunication system design requires signal integrity and reliability. When a T1/E1 primary line card has
a failure, it must be swapped with a backup line card while maintaining connectivity to a backplane without
losing data. System designers can achieve this by implementing common redundancy schemes with the
XRT83SL38 Line Interface Unit (LIU). The XRT83SL38 offers features that are tailored to redundancy
applications while reducing the number of components and providing system designers with solid reference
designs. These features allow system designers to implement redundancy applications that ensure reliability.
The Internal Impedance mode eliminates the need for external relays when using the 1:1 and 1+1 redundancy
schemes.
34