English
Language : 

XR19L400_09 Datasheet, PDF (32/46 Pages) Exar Corporation – SINGLE CHANNEL INTEGRATED UART AND RS-485 TRANSCEIVER
XR19L400
SINGLE CHANNEL INTEGRATED UART AND RS-485 TRANSCEIVER
REV. 1.0.3
EMSR[1:0]: Receive/Transmit FIFO Level Count (Write-Only)
When Scratchpad Swap (FCTR[6]) is asserted, EMSR bits 1-0 controls what mode the FIFO Level Counter is
operating in.
TABLE 10: SCRATCHPAD SWAP SELECTION
FCTR[6] EMSR[1] EMSR[0] Scratchpad is
0
X
X
Scratchpad
1
X
0
RX FIFO Level Counter Mode
1
0
1
TX FIFO Level Counter Mode
1
1
1
Alternate RX/TX FIFO Counter Mode
During Alternate RX/TX FIFO Level Counter Mode, the first value read after EMSR bits 1-0 have been
asserted will always be the RX FIFO Level Counter. The second value read will correspond with the TX FIFO
Level Counter. The next value will be the RX FIFO Level Counter again, then the TX FIFO Level Counter and
so on and so forth.
EMSR[3:2]: Reserved
For normal operation, these bits should remain a logic 0.
EMSR[5:4]: Extended RTS Hysteresis
TABLE 11: XON/XOFF HYSTERESIS
EMSR
BIT-5
EMSR
BIT-4
FCTR
BIT-1
FCTR
BIT-0
XON/XOFF
HYSTERESIS
(CHARACTERS)
0
0
0
0
0
0
0
0
1
±4
0
0
1
0
±6
0
0
1
1
±8
0
1
0
0
±8
0
1
0
1
±16
0
1
1
0
±24
0
1
1
1
±32
1
0
0
0
±40
1
0
0
1
±44
1
0
1
0
±48
1
0
1
1
±52
1
1
0
0
±12
1
1
0
1
±20
1
1
1
0
±28
1
1
1
1
±36
EMSR[6]: LSR Interrupt Mode
• Logic 0 = LSR Interrupt Delayed (for 16C2550 compatibility, default). LSR bits 2, 3, and 4 will generate an
interrupt when the character with the error is in the RHR.
• Logic 1 = LSR Interrupt Immediate. LSR bits 2, 3, and 4 will generate an interrupt as soon as the character is
received into the FIFO.