XR-2212
ELECTRICAL CHARACTERISTICS
Test Conditions: VCC = +12V, TA = + 25°C, R0 = 30kW, C0 = 0.033mF, unless otherwise specified. See
Figure 3 for component designation.
Parameter
General Characteristics
Supply Voltage
Supply Current
Oscillator Section
Frequency Accuracy
Frequency Stability
Temperature
Power Supply
Upper Frequency Limit
Lowest Practical Operating
Frequency
XR-2212M
XR-2212CP
Min. Typ. Max. Min. Typ. Max.
4.5
15 4.5
15
6
10
6
12
+1 +3
+1
+20 +50
+20
0.05 0.5
0.05
0.2
0.2
100 300
300
0.01
0.01
Timing Resistor, R0
Operating Range
Recommended Range
Oscillator Outputs
Voltage Output
Positive Swing, VOH
Negative Swing, VOL
Current Sink Capability
Current Output
Peak Current Swing
Output Impedance
Quadrature Output
Output Swing
DC Level
Output Impedance
Loop Phase Detector Section
Peak Output Current
Output Offset Current
Output Impedance
Maximum Swing
5
15
100
+150
+4
11
0.4
1
150
1
0.6
0.3
3
+200
+1
1
+5
2000
100
0.8
+300
5
15
+100
+4
11
0.5
1
150
1
0.6
0.3
3
+200
+2
1
+5
2000
100
+300
Units
Conditions
V
mA R0 > 10kW., See Figure 5
%
ppm/°C
%/V
%/V
kHz
Hz
Deviation from f0 = 1/R0C0
R1 = R
See Figure 9
VCC = 12 + 1V, See Figure 8
VCC = 5 + 0.5V, See Figure 8
R0 = 8.2kW, C0 = 400pF
R0 = 2MW, C0 = 50mF
See Figure 5
kW
kW See Figure 8 and Figure 9
Measured at Pin 5
V
V
mA
Measured at Pin 3
mA
MW
Measured at Pin 15
V
V
Referenced to Pin 11
kW
Measured at Pin 10
mA
mA
MW
V
Referenced to Pin 11
Note
Bold face parameters are covered by production test and guaranteed over operating temperature range.
Rev. 2.10
3