English
Language : 

SP6205EM5-L-3-3-TR Datasheet, PDF (3/15 Pages) Exar Corporation – 300mA/500mA Low Noise CMOS LDO Regulators
SP6203 / SP6205
300mA/500mA Low Noise CMOS LDO Regulators
Parameter
Turn-On Time (TON) 9
(from shutdown mode)
Turn-Off Time (TOFF)
Output Discharge Resistance
Enable Input Logic Low Voltage
Enable Input Logic High Voltage
Min.
1.6
Typ.
60
100
15
30
Max.
120
250
25
0.4
Units
µS
µS
Ω
V
V
Conditions
VIN ≥ 4V 10
IOUT = 30mA
IOUT = 0.1mA, VIN ≥ 4V 10
IOUT = 300mA, VIN ≥ 4V 10
No Load
• Regulator Shutdown
• Regulator Enabled
Note 2: Output voltage temperature coefficient is defined as the worst case voltage change divided by the total temperature
range.
Note 3: Regulation is measured at constant junction temperature using low duty cycle pulse testing. Changes in output
voltage due to heating effects are covered by the thermal regulation specification.
Note 4: Dropout-voltage is defined as the input to output differential at which the output voltage drops 2% below its
nominal value measured at 1V differential.
Note 5: Ground pin current is the regulator quiescent current. The total current drawn from the supply is the sum of the
load current plus the ground pin current.
Note 6: Output noise voltage is defined within a certain bandwidth, namely 10Hz < BW < 100kHz. An external bypass cap
(10nF) from reference output (BYP pin) to ground significantly reduces noise at output.
Note 7: Thermal regulation is defined as the change in output voltage at a time “t” after a change in power dissipation is
applied, excluding load and line regulation effects. Specifications are for a 300mA load pulse at VIN = 6V for t = 1ms.
Note 8: The wake-up time (TWU) is defined as the time it takes for the output to start rising after enable is brought high.
Note 9: The total turn-on time is called the settling time (TS), which is defined as the condition when both the output and
the bypass node are within 2% of their fully enabled values when released from shutdown.
Note 10: For output voltage versions requiring VIN to be lower than 4V, timing (TON & TOFF) increases slightly.
BLOCK DIAGRAM