EFR[5]: Special Character Detect Enable
⢠Logic 0 = Special Character Detect Disabled (default).
⢠Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= â10â) then flow control and special character work
normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= â01â) then flow control works
normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
interrupt, if enabled via IER bit-5.
EFR[7:6]: Reserved
For proper functionality, these bits should remain at a â0â.
4.16 Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Write Only
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, refer to âSection 2.12, Auto Xon/Xoff (Software) Flow Controlâ on page 11.