English
Language : 

SP336EEY-0A-EB Datasheet, PDF (23/30 Pages) Exar Corporation – 3.3V / 5V PROGRAMMABLE RS-232/RS-485/RS-422 SERIAL TRANSCEIVER
SP336E
REV. 1.0.1
3.3V / 5V PROGRAMMABLE RS-232/RS-485/RS-422 SERIAL TRANSCEIVER
2.0 SUGGESTED APPLICATION DIAGRAMS
The SP336E supports all signals used in RS-232 over an 8 pin modular jack (RJ-45) as defined in TIA/EIA-
561. For DTE serial port only three drivers are required. Driver_1 is not used in this configuration and its driver
input should be tied to high or low.
SP336E may also be used to implement a standard serial port over a DB-9 connector (TIA/EIA-574 or the
standard IBM serial port). In that case either DSR or RI signal can be supported. Both DSR and RI are used
mainly for dial-up connections and are typically not needed on dedicated lines. If both signals are required, add
a discrete transceiver such as SP3220E.
An alternative implementation would be to use the SP336E to emulate the functionality of two dual-channel
RS-232 transceivers (2 x SP232’s or equivalent).
Loop-Back
Changing from RS-232 mode (MODE 001) to loop-back mode (MODE 000) duplicates the function of an
external loop-back plug. Loop-back can be used to test serial port functionality or to diagnose faults.
FIGURE 24. RS-232E SERIAL PORT (EIA-561 / EIA-574)
23