XRP29302 Datasheet, PDF (2/9 Pages) Exar Corporation – 3A Low Dropout Voltage Regulator
XRP29302
3A Low Dropout Voltage Regulator
ABSOLUTE MAXIMUM RATINGS
These are stress ratings only and functional operation of
the device at these ratings or any other above those
indicated in the operation sections of the specifications
below is not implied. Exposure to absolute maximum
rating conditions for extended periods of time may affect
reliability.
Input Voltage VIN1................................................... 20V
Storage Temperature .............................. -65°C to 150°C
Lead Temperature (Soldering, 5 sec) ..................... 260°C
ESD Rating (HBM - Human Body Model) ..........................
All pins except EN................................................. 2kV
En pin ................................................................. 1kV
OPERATING RATINGS
Input Voltage Range VIN........................................... 16V
Junction Temperature Range ....................-40°C to 125°C
Thermal Resistance ......................................................
TO-220 Junction to Case @ TA ............................ 3°C/W
TO-220 Junction to Ambient ............................. 60°C/W
TO-263 Junction to Case @ TA ............................ 3°C/W
TO-263 Junction to Ambient ............................. 60°C/W
Note 1: Maximum positive supply voltage of 20V must be
of limited duration (<100ms) and duty cycle of less than
1%. The maximum continuous supply voltage is 16V.
ELECTRICAL SPECIFICATIONS
Specifications with standard type are for an Operating Junction Temperature of TJ = TA = 25°C only; limits applying over the
full Operating Junction Temperature range are denoted by a “•”. Minimum and Maximum limits are guaranteed through test,
design, or statistical correlation. Typical values represent the most likely parametric norm at TJ = 25°C, and are provided for
reference purposes only. Unless otherwise indicated, VIN = VOUT + 1V and IOUT=10mA, CIN = 6.8µF, COUT = 10µF, TA= 25°C.
Parameter
Line Regulation
Load Regulation
ΔV/ΔT
Dropout Voltage (note 3)
Min.
Ground Current (note 5)
Ground Pin Current at Dropout
Current Limit
3.0
Output Noise Voltage
Reference Voltage
1.228
1.215
Adjust Pin Bias Current
Reference Voltage
Temperature Coefficient
Adjust Pin Bias Current
Temperature Coefficient
Enable Input
Input Logic Voltage Low (OFF)
Input Logic Voltage High (ON)
2.4
Enable Input Pin
Regulator Output Current in
Shutdown
Typ.
0.06
0.2
20
120
380
525
600
30
40
0.9
4.5
400
260
1.24
40
20
0.1
100
10
Max.
0.5
1
100
300
650
800
60
1.252
1.265
80
120
Units
%
%
ppm/˚C
mV
mA
mA
A
µVRMS
V
V
nA
ppm/˚C
Conditions
IOUT=10mA, (VOUT+1V)≤VIN≤16V
VIN=VOUT + 1V, 10mA≤IOUT ≤IFL (note 2)
• VOUT Temp Coefficient (note 6)
• IOUT=100mA
IOUT=1.5A
• IOUT=2.5A, XRP29302A only
• IOUT=3A
• IOUT=1.5A
IOUT=3A
VIN = 0.5V less than specified VOUT IOUT=10mA
VOUT=0V (note 4)
10Hz-100KHz, IOUT=100mA, COUT=10µF
10Hz-100KHz, IOUT=100mA, COUT=33µF
•
•
Note 7
nA/˚C
0.8
600
750
1
2
500
•
V
• VIN<10V
• VEN=16V
µA
•
• VEN=0.8V
µA
• Note 8
Note 2: Full load current (IFL) is defined as 3.0A.
Note 3: Dropout voltage is defined (VIN-VOUT) when the output voltage drops to 99% of its nominal value.
Note 4: VIN=VOUT(nom)+1V. Use pulse-testing procedures to minimize temperature rise.
© 2013 Exar Corporation
2/9
Rev. 1.3.0