ABSOLUTE MAXIMUM RATINGS
These are stress ratings only and functional operation of
the device at these ratings or any other above those
indicated in the operation sections of the specifications
below is not implied. Exposure to absolute maximum
rating conditions for extended periods of time may affect
reliability.
Supply Voltage .......................................... -0.3V to 7.0V
Junction Temperature Range..................-40°C to +125°C
Storage Temperature .............................. -65°C to 150°C
OPERATING RATINGS
Operating Temperature Range ................. -40°C to +85°C
Thermal Resistance θJA .....................................160°C/W
Thermal Resistance θJC ...................................... 40°C/W
ELECTRICAL SPECIFICATIONS
Specifications with standard type are for an Operating Ambient Temperature of TA = 25°C only; limits applying over the full
Operating Junction Temperature range are denoted by a “•”. Minimum and Maximum limits are guaranteed through test,
design, or statistical correlation. Typical values represent the most likely parametric norm at TA = 25°C, and are provided
for reference purposes only. Unless otherwise indicated, VIN = 2.5V, VCNTL = 3.3V, VREF = 0.5xVIN, COUT = 10µF (ceramic),
TA= 25°C.
Parameter
Input Voltage Range (DDR 1/2)
VIN
Input Voltage Range (DDR 1/2)
VCNTL
Output Voltage VOUT
Output Offset Voltage VOS
Load Regulation (DDR 1/2) ∆VLOR
Quiescent Current IQ
Operating Current of VCNTL, ICNTL
Bias Current of VREF
Current Limit IIL
Thermal Protection
Thermal Shutdown Temperature
TSD
Thermal Shutdown Hysteresis
Shutdown Specifications
Shutdown Threshold VTRIGGER
Min.
1.6
3.0
-20
2.2
125
0.8
Typ.
2.5/1.8
3.3
VREF
10
10
8
3
3
150
30
Max.
3.6
+20
25
25
30
10
1
4.5
0.2
Units
V
V
V
mV
mV
mV
µA
mA
µA
A
°C
°C
V
Conditions
(note 4)
Keep VCNTL≥VIN on operation power on
and power off sequences
(note 4)
IOUT = 0mA
IOUT = 0mA
No load
IOUT = 0.1mA to +2A
IOUT = 0.1mA to -2A
VREF < 0.2V, VOUT = OFF
No load
VREF = 1.25V
(note 3)
(note 4)
3.3V ≤ VCNTL ≤ 5V, guaranteed by design
Guaranteed by design
Output ON
VREF = 0V Æ 1.25V
Output OFF
VREF = 1.25V Æ 0V
Note 1: VOS offset is the voltage measurement defined as VOUT subtracted from VREF.
Note 2: Load regulation is measured at constant junction temperature, using pulse testing with a low ON time.
Note 3: Current limit is measured by pulsing a short time.
Note 4: In order to safely operate your system, VCNTL must be > VIN.
© 2010 Exar Corporation
2/9
Rev. 2.0.0