c) Calculate R1 to set the bandwidth +Df (See design equation 5):
R1
+
R0·fO·2
Df
+
20,
000·1,
100
000·2
+
400K
Note: The total detection bandwidth covers the frequency range of fO +Df
d) Calculate value of C0 for a given loop damping factor:
Normally, j = 0.5 is recommended.
C1
+
1250·C0
R1·j2
+
1250·50·10–9
400, 000·0.52
+
6.25pF
Increasing C1 improves the out-of-band signal rejection, but increases the PLL capture time.
e) Calculate value of the filter capacitor CD . To avoid chatter at the logic output, with RD = 470KW, CD must be:
CD
+
16
Df
w
16
200
w
80nF
Increasing CD slows down the logic output response time.
f) Fine tune center frequency with 5KW potentiometer, RX.