XR-T5793
Output Transformer Selection
The 1:1.265 ratio output transformer is recommended for
the XR-T5793 because this ratio gives the best possible
transmitter output return loss for 120⦠balanced E1
service. However, other transformers may provide an
adequate return loss for many applications. The two
characteristics that determine series build-out resistor
requirements are:
D Driver output impedance is less than 5â¦.
D Vs, which is the driver open circuit output voltage, is
4.5V peak.
The following method may be used to determine
transformer suitability for a given use.
1. List the application requirements.
Transformer ratio = 1:n
VO = Peak output pulse amplitude
RL = Load resistance
Rs
1:n
3
1
Vs
VO
RL
4
2
Figure 5. Equivalent Impedance Schematic
3. Calculate the source resistance, Rs.
Ç Ç RS + Req
VS
Veq
*
1
4. Now calculate the theoretical return loss.
Ç Ç Return Loss + 20 log
Req ) RS
Req * RS
The calculation given below uses the recommended
1:1.265 ratio transformer as an example:
Transformer Ratio = 1:1.265
VO = 3.0V Peak
RL = 120â¦
Req
+
RL
n2
+
120
1.6
+
75â¦
Veq
+
Vo
n
+
3.0
1.265
+
2.37V
Ç Ç Ç Ç Rs + Req
VS
Veq
*
1
+ 75
4.5
2.37
*
1
+ 67.4â¦
2. Calculate equivalent output voltage and load
resistance without the transformer.
Req
+
RL
n2
Veq
+
VO
n
(Datasheet specifies standard value of 68â¦)
Calculate the theoretical return loss to determine if the
transformer is acceptable.
Rs
Ç Ç Return Loss + 20 log
75 ) 67.4
75 * 67.4
+ 25.5dB
Vs
Req
Veq
Figure 6. Equivalent Simplified Schematic
Rev. 2.00