English
Language : 

XR79206EL-F Datasheet, PDF (11/20 Pages) Exar Corporation – 40V, 6A Synchronous Step-Down COT Power Module
XR79206
Applications Information
Functional Description
XR79206 is a synchronous step-down proprietary
emulated current-mode Constant On-Time (COT) module.
The on-time, which is programmed via RON,
is inversely proportional to VIN and maintains a nearly
constant frequency. The emulated current-mode control is
stable with ceramic output capacitors.
Each switching cycle begins with GH signal turning on
the high-side (switching) FET for a preprogrammed time.
At the end of the on-time, the high-side FET is turned off
and the low-side (synchronous) FET is turned on for a
preset minimum time (250ns nominal). This parameter is
termed minimum off-time. After the minimum off-time, the
voltage at the feedback pin FB is compared to an internal
voltage ramp at the feedback comparator. When VFB drops
below the ramp voltage, the high-side FET is turned on
and the cycle repeats. This voltage ramp constitutes an
emulated current ramp and makes possible the use of
ceramic capacitors, in addition to other capacitor types,
for output filtering.
Enable/Mode Input (EN/MODE)
EN/MODE pin accepts a tri-level signal that is used to control
turn on/off. It also selects between two modes of operation:
forced CCM and DCM/CCM. If EN is pulled below 1.8V,
the module shuts down. A voltage between 2.0V and 2.8V
selects the forced CCM mode which will run the module in
continuous conduction at all times. A voltage higher than
3.1V selects the DCM/CCM mode which will run the module
in discontinuous conduction at light loads.
Selecting the Forced CCM Mode
In order to set the module to operate in forced CCM, a voltage
between 2.0V and 2.8V must be applied to EN/MODE.
This can be achieved with an external control signal
that meets the above voltage requirement. Where an
external control is not available, the EN/MODE can be
derived from VIN. If VIN is well regulated, use a resistor
divider and set the voltage to 2.5V. If VIN varies over a
wide range, the circuit shown in Figure 25 can be used
to generate the required voltage. Note that at VIN of
5.0V and 40V the nominal Zener voltage is 4.0V and
5.0V respectively. Therefore for VIN in the range of 5.0V
to 40V, the circuit shown in Figure 25 will generate VEN
required for forced CCM.
Selecting the DCM/CCM Mode
In order to set the module operation to DCM/CCM, a voltage
between 3.1V and 5.5V must be applied to EN/MODE pin.
If an external control signal is available, it can be directly
connected to EN/MODE. In applications where an external
control is not available, EN/MODE input can be derived
from VIN. If VIN is well regulated, use a resistor divider
and set the voltage to 4V. If VIN varies over a wide range,
the circuit shown in Figure 26 can be used to generate the
required voltage for DCM/CCM operation.
VIN
RZ
10k
Zener
MMSZ4685T1G or
Equivalent
R1
30.1k, 1%
R2
EN/MODE
35.7k, 1%
Forced CCM, wide VIN range
Figure 25. Selecting Forced CCM by
Deriving EN/MODE from VIN
VIN
Zener
MMSZ4685T1G or
Equivalent
RZ
10k
VEN
EN/MODE
DCM/CCM, wide VIN range
Figure 26. Selecting DCM/CCM by
Deriving EN/MODE from VIN
REV1B
11/19