After calculation, we find that in such an
LAYOUT CONSIDERATIONS
a2p60pl.i6cmaPtAio$.nD(oSi/Png6'2t0h25e)stha em6ree3calcguulalatitoonrs isfolirmZtihteeLdOtoOOLPTpahLcekWpargimeWaisrKy vpHiaaththoUef HhpeaJactkXcaogOnedDuleWadRs.UcTti¶ohneVroeufot roef,the
output current to 260.9mA.
careful considerations have to be taken into
account:
Also, taking advantage of the very low dropout
voltage characteristics of the SP6203/6205,
power dissipation can be reduced by using the
lowest possible input voltage to minimize the
input - to - output drop.
1) Attaching the part to a larger copper
footprint will enable better heat transfer from
WKH GHYLFH HVSHFLDOO\ RQ 3&
are int ernal ground and power planes.
A DJUSTABLE REGULATOR A PPLICATIONS
2) Place the input, output and bypass
capacitors close to the device for optimal
The SP6203/6205 can be adjusted to a specific
transient response and device behavior.
output voltage by using two external resistors
3) Connect all ground connections directly to
(see functional diagram). The resistors
set the
WKH JURXQG SODQH ,Q FDVH WK
output voltage based on the following
plane, connect to a common local ground point
equation:
before connecting to board ground.
VOUT = V REF *(R1/R2 + 1)
Resistor values are not critical because ADJ
(adjust) has a high input impedance, but for
best performance use resistors of 470K Ÿ or
less. A bypass capacitor from ADJ to V OUT
provides improved noise performance.
Such layouts will provide a much better
thermal conductivity (lower
LJJA) for, a higher
maximum allowable power dissipation limit.
D UAL - SUPPLY OPERATION
When used in dual supply systems where the
regulator load is returned to a negative
supply, the output voltage must be diode
clamped to ground.