DESCRIPTION
TMA (Synchronous Timing Module, model A) parts serve as a frequency
translator in telecommunications systems. The device translates any CMOS
input reference frequencies (8, 16, 32, 64kHz up to 77.760MHz) into
jitter-attenuated, phase locked reference synchronized output frequencies
up to 77.760MHz.
OUTLINES & DIMENSIONS
Page 1 of 2
FEATURES
Loss of Reference (LOR) and Loss of Lock (LOL) active alarms.
Continuous input reference monitoring of external references.
Automatic FREE RUN mode on Loss Of Reference (LOR)
±15ppm output accuracy guaranteed.
Manually forced FREE-RUN mode by software control.
Tristate (output high impedance) for external testing.
+3.3V leadframe package, current <80mA.
1 second acquisition time
GENERAL SPECIFICATION
Input Reference Frequency:
Output Frequency:
Supply Voltage:
Current Consumption:
Input Jitter Tolerance:
Acquisition Time:
Capture/Pull-in Range:
Input Logic:
Output Logic:
Duty Cycle:
Rise and Fall Times:
Free Run Accuracy:
Jitter at 77.760MHz:
Operating Temperature Range
COMMERCIAL:
INDUSTRIAL:
8, 16, 32 or 64kHz or <77.76MHz
Selectable by SELA & SELB pads
from 1.544MHz to 77.760MHz
+3.3 Volts ±5%
Less than 80mA
2us at 10Hz
1 second
±40ppm
CMOS
CMOS
40%60% at 50% level
2ns (20%~80% output levels)
±15ppm maximum
7.5ps RMS typ. at 10Hz~1MHz
12kHz to 20MHz bandwidth
0°~+70°C (Code âCâ)
-40°~+85°C (Code âIâ)
ABSOLUTE MAXIMUM RATINGS
Symbol
Vcc
Vin
Tstg
Tref
Description
Supply Voltage relative to ground
Input Voltage relative to ground
Storage Temperature (Ambient)
Maximum reflow Temperature
Rating
-0.5V to 4.0V
-0.5V to 5.5V
-65° to +150°C
240°C
PAD CONNECTIONS
Pad No. Pad Name
1
REF OP
2
NC
3
NC
4
GND
5
FREE RUN
6
LOR
7
LOL
8
REFIN
9
OUTPUT
10
E/D
11
VCC
12
TDO
13
SEL A
14
SEL B
Description of Function
Reference Output
Do not connect - factory use only
Do not connect - factory use only
Ground
Control input to force FREE RUN
Logic 1 indicates Loss Of Reference
Logic 1 indicates Loss Of Lock
Reference input
VCXO output
Enable/Disable output
Supply Votage
Do not connect - factory use only
Second bit reference frequency selection
First bit reference frequency selection
FUNCTIONAL BLOCK DIAGRAM
PART NUMBERS
Part numbers are generated according to this scheme:
Supply
Voltage
Package
Type
Operating
Temperature
Range
Input
Frequency
Output
Frequency
â3â for +3.3 V TMA20
âCâ=0°~+70°C
âIâ=-40°~+85°C
Add âkâ
for kHz
Output
Frequency
in MHz
EXAMPLE: 3TMA20-C-8K-77.760
Representing: +3.3V supply, TMA package, Commercial operating
temperature range, 8kHz input frequency and output frequency of
77.760MHz.
EUROQUARTZ LIMITED Blacknell Lane CREWKERNE Somerset UK TA18 7HE
Tel: +44 1460 230000 Fax: +44 1460 230001 email: info@euroquartz.co.uk web: www.euroquartz.co.uk
|
▷ |