English
Language : 

DD82S Datasheet, PDF (3/3 Pages) eupec GmbH – Marketing Information
DD 82 S
300
Qr
[µAs]
200
100
IFM = 1280 A
640 A
320 A
160 A
80 A
40 A
20 A
300
IRM
[A]
200
100
IFM = 1280 A
640 A
320 A
160 A
80 A
40 A
20 A
10 A
10 A
0
50
100
150
200
250
DD 82 S/1
-diF/dt [A/µs]
Bild / Fig. 1
Sperrverzögerungsladung Qr = f(-di/dt), tvj = tvj (max), vR ≤ 0,5 VRRM,
vRM = 0,8 VRRM /
Recovered charge Qr = f(-di/dt), tvj = tvj (max), vR ≤ 0,5 VRRM,
vRM = 0,8 VRRM
Parameter: Durchlaßstrom / On-state current IFM
0
50
100
150
200
250
DD 82 S/2
-diF/dt [A/µs]
Bild / Fig. 2
Rückstromspitze IRM= f(-di/dt), tvj = tvj (max), vR ≤ 0,5 VRRM, vRM = 0,8 VRRM
Peak reverse recovery current IRM = f(-di/dt), tvj = tvj (max), vR ≤ 0,5 VRRM,
vRM = 0,8 VRRM
Parameter: Durchlaßstrom / On-state current ITM
0.64
0.56
Z(th) JC
0.48
[°C/W]
0.40
1. Konstantstrom
2. Sinus, F=50Hz, Stromflußwinkel: 180°
3. Rechteck, F=50Hz, Stromflußwinkel: 180°
4. Rechteck, F=50Hz, Stromflußwinkel: 120°
5. Rechteck, F=50Hz, Stromflußwinkel: 60°
0.32
0.24
0.16
5.
0.08
4.
3.
2.
1.
0
10-3
10-2
10-1
100
DD 82 S/3
101
102
T [s]
Bild / Fig. 3
Transienter innerer Wärmewiderstand ZthJC für einen Zweig
bei sinus- und trapezförmigem Stromverlauf
Transient thermal impedance ZthJC, junction to case per arm
at sinussoidal and trapezoidal waveform.
Analytische Elemente des transienten Wärmewiderstandes ZthJC pro Zweig für DC
Analytical elements of transient thermal impedance ZthJC per arm for DC
Pos. n
1
2
3
4
5
6
7
R thn[°C/W]
τn [s]
0,0102
0,00112
0,0329
0,0175
0,0805
0,322
0,0741
1,21
0,072
7,5
Analytische Funktion / Analytical function:
Σnmax
ZthJC =
Rthn
-
(1-e
t
τn
)
n=1