English
Language : 

BMC150 Datasheet, PDF (83/141 Pages) List of Unclassifed Manufacturers – 6-axis eCompass
int_fwm_en:
int_ffull_en:
data_en
low_en:
high_en_z:
high_en_y:
high_en_x:
Datasheet
eCompass BMC150
Page 83
Confidential
FIFO watermark interrupt: ‘0’disabled, or ‘1’ enabled
FIFO full interrupt: ‘0’disabled, or ‘1’ enabled
data ready interrupt: ‘0’disabled, or ‘1’ enabled
low-g interrupt: ‘0’disabled, or ‘1’ enabled
high-g interrupt, z-axis component: ‘0’disabled, or ‘1’ enabled
high-g interrupt, y-axis component: ‘0’disabled, or ‘1’ enabled
high-g interrupt, x-axis component: ‘0’disabled, or ‘1’ enabled
Register 0x18 (INT_EN_2)
Controls which interrupt engines in group 2 are enabled.
Name
Bit
Read/Write
Reset
Value
Content
0x18
7
R/W
0
INT_EN_2
6
5
4
R/W
R/W
R/W
0
0
0
reserved
Bit
Read/Write
Reset
Value
Content
3
R/W
0
slo_no_mot_sel
2
1
0
R/W
R/W
R/W
0
0
0
slo_no_mot_en_z slo_no_mot_en_y slo_no_mot_en_x
reserved:
write ‘0’
slo_no_mot_sel: select ‘0’slow-motion, ‘1’ no-motion interrupt function
slo_no_mot_en_z: slow/n-motion interrupt, z-axis component: ‘0’disabled, or ‘1’ enabled
slo_no_mot_en_y: slow/n-motion interrupt, y-axis component: ‘0’disabled, or ‘1’ enabled
slo_no_mot_en_x: slow/n-motion interrupt, x-axis component: ‘0’disabled, or ‘1’ enabled
Register 0x19 (INT_MAP_0)
Controls which interrupt signals are mapped to the INT1 pin.
Name
Bit
Read/Write
Reset
Value
Content
0x19
7
R/W
0
int1_flat
6
R/W
0
int1_orient
INT_MAP_0
5
R/W
0
int1_s_tap
4
R/W
0
int1_d_tap
BST-BMC150-DS000-03 | Revision 0.4 | February 2013
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice. Not intended for publication.