English
Language : 

NPX-25T Datasheet, PDF (8/12 Pages) List of Unclassifed Manufacturers – SELECTION GUIDE
GENESIS EP performance specifications
Constant current discharge/amps to 1.67Vpc @ 25°C
Products
DURATION
5 min
10 min
15 min
30 min
60 min
90 min
5 hr
8 hr
10 hr
20 hr
G13EP (13Ah)
70.8
43.6
32.2
18.6
10.4
7.3
2.5
1.6
1.3
.7
G16EP (16Ah)
90.0
54.8
40.1
23.0
12.7
8.9
3.0
2.0
1.6
.8
G26EP (26Ah)
143.4
90.7
67.4
39.0
21.7
15.1
5.0
3.2
2.6
1.4
G42EP (42Ah)
212.0
138.4
104.1
60.8
33.8
23.5
7.9
5.1
4.2
2.3
Constant current discharge/watts per cell to 1.67Vpc @ 25°C
Products
DURATION
5 min
10 min
15 min
30 min
60 min
90 min
5 hr
8 hr
10 hr
20 hr
G13EP (13Ah)
758.4
481.8
361.2
231.6
121.2
85.8
29.4
19.2
15.6
8.4
G16EP (16Ah)
975.6
609.6
453.6
264.6
190.2
105.0
36.0
23.4
19.2
10.2
G26EP (26Ah)
1532
995
751
444
251
175.8
59
38
31
16
G42EP (42Ah)
2291
1540
1173
698
394
276
94
62
51
28
Charging/Temperature/Life:
CHARGING PER CELL
Products
Cyclic
Float
G13EP, G16EP
G26EP & G42EP
G13EPX, G16EPX
G26EPX & G42EPX
CV 14.7-15.0
CC*
CV 14.7-15.0
CC*
CV 13.5-13.8
CC*
CV 13.5-13.8
CC*
TEMPERATURE RANGE
Storage &
discharge
Charge
-40°C to +45°C
-40°C to +45°C
-40°C to +60°C
-40°C to +60°C
Maximum recommended storage time before recharge - 24 months @ 25°C or 2.0Vpc, whichever is earlier
Atmospheric pressure range - Vacuum to 2 atmospheres
Terminal attachment torque for G13EP & G16EP - 50 in.-lbs (5.6 nm)
Terminal attachment torque for G26EP & G42EP - 60 in.-lbs (6.8 nm)
*Users planning to use CC should consult the EnerSys Application Support Department
GENESIS EP mechanical specifications (A, B & C - Maximum)
Products
A
in. mm
B
in. mm
DIMENSIONS
C
in. mm
D
in. mm
G13EP
G13EPX
G16EP
G16EPX
G26EP
G26EPX
G42EP
G42EPX
6.910
6.998
7.150
7.267
6.565
6.636
7.775
7.866
175.51
177.75
181.61
184.58
166.75
168.55
197.49
199.80
3.282
3.368
3.005
3.107
6.920
7.049
6.525
6.659
83.36
85.55
76.33
78.92
175.77
179.04
165.74
169.14
5.113
5.165
6.605
6.666
4.957
5.040
6.715
6.803
129.87
131.19
167.77
169.32
125.91
128.02
170.56
172.80
5.56 141.2
5.56 141.2
5.74 145.8
5.74 145.8
0.64 16.3
0.69 17.5
0.74 18.8
0.79 20.1
LIFE EXPECTANCY
C/5 Cycle life
100% DOD
Float life at
25°C (20°C)
400
10 years
(15 years)
400
10 years
(15 years)
E
in. mm
0.81 20.6
0.81 20.6
0.67 16.9
0.67 16.9
1.06 27.0
1.11 28.2
0.87 22.0
0.91 23.2
Weight
lb. kg
10.8 4.9
12.0 5.4
13.5 6.1
14.7 6.7
22.3 10.1
23.8 10.8
32.9 14.9
35.1 15.9
UL Recognized Component. Meets UL 1989
Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container
Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact EnerSys Customer Service for details.
8
www.enersys.com
Publication No: US-GPL-SG-002 - July 2006