English
Language : 

SGN04G72G2BK2MT-DCWRT Datasheet, PDF (7/17 Pages) List of Unclassifed Manufacturers – 4096MB DDR3 – SDRAM ECC SO-DIMM
Data Sheet
Rev.1.0 24.07.2013
IDD Specifications and Conditions
(0°C ≤ TCASE ≤ + 85°C; VDDQ = +1.5V ± 0.075V, VDD = +1.5V ± 0.075V)
Parameter
& Test Condition
OPERATING CURRENT *) :
One device bank Active-Precharge;
tRC= tRC (IDD); tCK = tCK (IDD); CKE is HIGH, CS# is HIGH
between valid commands;
DQ inputs changing once per clock cycle; Address and
control inputs changing once every two clock cycles
OPERATING CURRENT *) :
One device bank; Active-Read-Precharge;
IOUT = 0mA; BL = 4, CL = CL (IDD), AL = 0;
tCK = tCK (IDD), tRC= tRC (IDD), tRAS = tRAS MIN (IDD),
tRCD = tRCD (IDD); CKE is HIGH, CS# is HIGH between
valid commands; Address inputs changing once every
two clock cycles; Data Pattern is same as IDD4W
PRECHARGE POWER-DOWN
Slow Exit
CURRENT:
All device banks idle; Power-down mode;
tCK = tCK (IDD); CKE is LOW; All Control and Fast Exit
Address bus inputs are not changing; DQ’s
are floating at VREF
PRECHARGE QUIET STANDBY CURRENT:
All device banks idle;
tCK = tCK (IDD); CKE is HIGH, CS# is HIGH;
All Control and Address bus inputs are not changing;
DQ’s are floating at VREF
PRECHARGE STANDBY CURRENT:
All device banks idle;
tCK = tCK (IDD); CKE is HIGH, CS# is HIGH;
All other Control and Address bus inputs are changing
once every two clock cycles; DQ inputs changing once
per clock cycle
ACTIVE POWER-DOWN CURRENT:
All device banks open; tCK = tCK (IDD); CKE is LOW; All
Control and Address bus inputs are not changing; DQ’s
are floating at VREF (always fast exit)
ACTIVE STANDBY CURRENT:
All device banks open; tCK = tCK (IDD),
tRAS = tRAS MAX (IDD), tRP = tRP (IDD);
CKE is HIGH, CS# is HIGH between valid commands;
All other Control and Address bus inputs are changing
once every two clock cycles; DQ inputs changing once
per clock cycle
OPERATING READ CURRENT *):
All device banks open, Continuous burst reads; One
module rank active; IOUT = 0mA; BL = 4, CL = CL (IDD),
AL = 0; tCK = tCK (IDD), tRAS = tRAS MAX (IDD), tRP = tRP
(IDD); CKE is HIGH, CS# is HIGH between valid
commands; Address bus inputs are changing once
every two clock cycles; DQ inputs changing once per
clock cycle
Symbol
IDD0
IDD1
IDD2P
IDD2Q
IDD2N
IDD3P
IDD3N
IDD4R
12800-11-11-11
738
828
216
666
720
774
900
990
1512
10600-9-9-9
693
783
216
576
630
684
810
900
1377
Unit
mA
mA
mA
mA
mA
mA
mA
mA
Swissbit AG
Industriestrasse 4
CH – 9552 Bronschhofen
Fon: +41 (0) 71 913 03 03
Fax: +41 (0) 71 913 03 15
www.swissbit.com
eMail: info@swissbit.com
Page 7
of 17