English
Language : 

L1T2-3070000000000_14 Datasheet, PDF (7/19 Pages) List of Unclassifed Manufacturers – Extreme efficacy that will transform your next market leading luminaire
Level
1
JEDEC Moisture Sensitivity
Table 5.
Time
unlimited
Floor Life
Conditions
[ 30°C /
85% RH
Soak Requirements
Standard
Time
Conditions
168h
+5/-0
85°C / 85%
RH
Reflow Soldering Characteristics
Figure 1. Temperature profile for Table 6.
Table 6.
JEDEC 020c
Profile Feature
Average Ramp-Up Rate ( Ts to T )
max
p
Preheat Temperature Min ( Ts )
min
Preheat Temperature Max ( Tsmax )
Preheat Time ( ts to ts )
min
max
Liquidus Temperature ( TL )
Time Maintained Above Time ( t )
L
Peak / Classification Temperature ( TP )
Time Within 5°C of Actual Peak Temperature ( t )
P
Ramp-Down Rate
Time 25°C to Peak Temperature
Lead Free Assembly
3°C / second max
150°C
200°C
60 - 180 seconds
217°C
60 - 150 seconds
260°C
20 - 40 seconds
6°C / second max
8 minutes max
LUXEON TX Datasheet DS133 20140224 ©2014 Philips Lumileds Lighting Company.
6