English
Language : 

240D25-17 Datasheet, PDF (7/12 Pages) List of Unclassifed Manufacturers – SOLID-STATE RELAYS
DATA SHEET
Form 859-990514
SOLID-STATE RELAYS
page 7/12
Specifications
AC Power - Printed Circuit Package (P & MP Series)
M odel
Number
Nominal
AC Line
Voltage
Nominal
Current
Rating
Amps
1 cycle
Surge
(Amps)
Pea k
Nominal
Signal Input
Resistance
(Ohms)
Signal
Pick-up
Voltage
Signal
Drop-out
Voltage
Peak Maximum
Repetitive Output
Voltage Voltage
Maximum Drop
Off-State
Leakage
mA
M aximum
Opera ting
Voltage
Range
(Volts AC)
M P120D2
or P120D2
120
2
20
100 0
3VDC**
(32V
all owed )
1 VDC
600
1.6 volts 5 mA
12-14 0
M P120D4
or P120D4 120
4
85
100 0
3VDC**
(32V
all owed )
1 VDC
600
1.6 volts 5 mA
12-14 0
M P240D2
or P240D2 240
2
20
100 0
3VDC**
(32V
all owed )
1 VDC
600
1.6 volts 5 mA
24-28 0
M P240D4
240
4
85
or P240D4
100 0
3VDC**
(32V
all owed )
1 VDC
600
1.6 volts 5 mA
24-28 0
MP380D4 380
4
85
100 0
3VDC∗∗
(32V
all owed )
1 VDC
800
1.6 volts 5 mA
24-42 0
Notes: θjc* = Thermal resistance junction to base. Maximum junction temperature is 110°C.
** = MP Series 24 volts maximum.
I2 t
Rating
t=8.3
(ms )
2
30
2
30
30
Isolation θjc* Dissipation
Voltage °C/Watt Watts/Amp
4,000 VRM S 20
1. 2
4,000 VRM S 6.5
1. 2
4,000 VRM S 20
1. 2
4,000 VRM S 6.5
1. 2
4,000 VRM S 6.5
1. 2
Surge Current Data
2-Amp 4-Amp
Time Time* P or MP P or MP
Second (Cycles) Peak Peak
Amps Amps
0.017
1
20
85
0.050
3
18
66
0.100
6
15
53
0.200
12
11
45
0.500
30
9
37
1
60
8.5
31
2
120
8
28
3
180
7.5
27
4
240
7
26
5
300
6.5
25
10
600
6
24
Note: *60 HZ
Dimensional Drawings
Model
P240D4
Model
MP240D4
Opto 22 • 43044 Business Park Drive • Temecula, CA 92590 • Phone: (909)695-3000 • (800)321-OPTO • Fax: (909)695-3095 • Internet: www.opto22.com
Inside Sales: (800)452-OPTO • Product Support: (800)TEK-OPTO • (909)695-3080 • Fax: (909)695-3017 • E-mail: support@opto22.com • FaxBack: (800)474-OPTO