English
Language : 

FEDL9445-02 Datasheet, PDF (68/84 Pages) List of Unclassifed Manufacturers – 180-Channel LCD Driver with Built-in RAM for LCD Dot Matrix Displays
FEDL9445-02
ML9445
Multiplier Clock Frequency Select (2-byte command)
This command selects the multiplier clock frequency of the 1st and 2nd voltage multiplier circuits. This command is
a 2-byte command to be used together with the multiplier clock frequency select mode set command and the
multiplier clock frequency select register set command. So, be sure to set the both commands continuously.
• Multiplier Clock Frequency Select mode set (Write)
When this command is input, the multiplier clock frequency select register set command becomes valid. Once the
multiplier clock frequency select mode is selected, any command other than the multiplier clock frequency select
register set command cannot be used. This status is released when any data is stored in the register by the multiplier
clock frequency select register set command.
A0
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
1
0
1
0
1
0
1
• Multiplier Clock Frequency register set (Write)
Setting of data in the multiplier clock frequency select register by this command allows specification of the
multiplier clock frequency. The multiplier clock frequency select mode is released when the multiplier clock
frequency select register is set by inputting this command.
Frequency
Internal Clock External Clock
fOSC/64
fEXT/8
fOSC/32
fEXT/4
fOSC/16
fEXT/2
A0 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
1
*
Sequence of setting the multiplier clock frequency register:
Multiplier Clock Frequency mode set
Multiplier Clock Frequency register set
The Multiplier Clock Frequency mode is released
NOP (Write)
This is a No Operation command.
A0
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
1
1
1
0
0
0
1
1
68/84