English
Language : 

BMA280 Datasheet, PDF (62/119 Pages) List of Unclassifed Manufacturers – Digital, triaxial acceleration sensor
BMA280
Data sheet
Page 62
Register 0x0F (PMU_RANGE)
The register allows the selection of the accelerometer g-range.
Name
0x0F
PMU_RANGE
Bit
7
6
5
4
Read/Write R/W
R/W
R/W
R/W
Reset
0
0
0
0
Value
Content
Reserved
0
Bit
3
2
1
0
Read/Write R/W
R/W
R/W
R/W
Reset
0
0
1
1
Value
Content
range<3:0>
range<3:0>:
reserved:
Selection of accelerometer g-range:
´0011b´  ±2g range; ´0101b´  ±4g range; ´1000b´  ±8g range;
´1100b´  ±16g range; all other settings  ±2g range
write ‘0’
Register 0x10 (PMU_BW)
The register allows the selection of the acceleration data filter bandwidth.
Name
0x10
PMU_BW
Bit
7
6
5
Read/Write R/W
R/W
R/W
Reset
0
0
0
Value
Content
Reserved
0
Bit
3
2
1
Read/Write R/W
R/W
R/W
Reset
1
1
1
Value
Content
bw<3:0>
4
R/W
0
bw<4>
0
R/W
1
bw<4:0>:
reserved:
Selection of data filter bandwidth:
´00xxxb´  7.81 Hz, ´01000b´  7.81 Hz, ´01001b´  15.63 Hz,
´01010b´  31.25 Hz, ´01011b´  62.5 Hz, ´01100b´  125 Hz,
´01101b´  250 Hz,
´1xxxxb´  ODRmax.
´01110b´  500 Hz, ´01111b´  ODRmax.,
write ‘0’
BST-BMA280-DS000-09 | Revision 1.6 | May 2013
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.