SM9541-010C-S-C-213-S Datasheet, PDF (5/11 Pages) List of Unclassifed Manufacturers – Ultra-Low Pressure Digital Sensor | |||
|
◁ |
⢠I2C Read_MR â Measurement Request:
o Slave starts a measurement and DSP calculation cycle.
o Start Condition â Device Slave Address [6:0] â Read/Write Bit (Read = 1) â Wait for Slave ACK â Stop Condition
S6543210RAS
⢠I2C Read_DF2 â Data Fetch 2 Bytes:
o Slave returns only pressure data to the master in 2 bytes.
o Start Condition â Device Slave Address [6:0] â Read/Write Bit (Read = 1) â Wait for Slave ACK â 2 status bits â 6 pressure
bits [13:8] â Master ACK â 8 pressure bits [7:0] â Master NACK â Stop Condition
S 6 5 4 3 2 1 0 R A 15 14 13 12 11 10 9 8 A 7 6 5 4 3 2 1 0 N S
o I2C Read_DF3 â Data Fetch 3 Bytes:
Slave returns 2 pressure data bytes and temperature high byte [10:3] to the master.
Start Condition â Device Slave Address [6:0] â Read/Write Bit (Read = 1) â Wait for Slave ACK â 2 status bits â 6 pressure
bits [13:8] â Master ACK â 8 pressure bits [7:0] â Master ACK â 8 temperature bits [10:3] â Master NACK â Stop Condition
S 6 5 4 3 2 1 0 R A 15 14 13 12 11 10 9 8 A 7 6 5 4 3 2 1 0 A 10 9 8 7 6 5 4 3 N S
⢠I2C Read_DF4 â Data Fetch 4 Bytes:
o Slave returns 2 pressure data bytes and and 2 temperature bytes ([10:3] and [2:0]xxxxx) to the master.
o Start Condition â Device Slave Address [6:0] â Read/Write Bit (Read = 1) â Wait for Slave ACK â 2 status bits â 6 pressure
bits [13:8] â Master ACK â 8 pressure bits [7:0] â Master ACK â 8 temperature bits [10:3] â Master ACK â 3 temperature
bits [3:0] â Master NACK â Stop Condition
S 6 5 ⦠1 0 R A 15 14 13 12 ⦠9 8 A 7 6 ⦠1 0 A 10 9 ⦠4 3 A 2 1 0 x x x x x N S
|
▷ |