English
Language : 

RGE300 Datasheet, PDF (5/11 Pages) List of Unclassifed Manufacturers – Selection Guide and Product Data
5. Verify ambient operating conditions.
RGE
Radial Leaded
Ensure that your application’s minimum and maximum ambient
temperatures are within the operating temperature range of –40°C
and 85°C.
Maximum device surface temperature in the tripped state is 125°C.
6. Verify the RGE device’s dimensions.
Using dimensions from the table below, compare the dimensions of the
RGE device you selected with the application’s space considerations.
Product dimensions (millimeters/inches)
Part
A
B
C
D
E
F
number
max.
max.
typ.
min.
max.
typ.
RGE300
7.1 (0.28) 11.0 (0.43)
5.1 (0.20)
7.6 (0.30)
3.0 (0.12)
1.2 (0.05)
New RGE400
8.9 (0.35) 12.8 (0.50)
5.1 (0.20)
7.6 (0.30)
3.0 (0.12)
1.2 (0.05)
RGE500
New RGE600
10.4 (0.41)
10.7 (0.42)
14.3 (0.56)
17.1 (0.67)
5.1 (0.20)
5.1 (0.20)
7.6 (0.30)
7.6 (0.30)
3.0 (0.12)
3.0 (0.12)
1.2 (0.05)
1.2 (0.05)
4
RGE700 11.2 (0.44) 19.7 (0.78)
5.1 (0.20)
7.6 (0.30)
3.0 (0.12)
1.2 (0.05)
New RGE800 12.7 (0.50) 20.9 (0.82)
5.1 (0.20)
7.6 (0.30)
3.0 (0.12)
1.2 (0.05)
RGE900 14.0 (0.55) 21.7 (0.85)
5.1 (0.20)
7.6 (0.30)
3.0 (0.12)
1.2 (0.05)
New RGE1000 16.5 (0.65) 24.1 (0.95)
5.2 (0.20)
7.6 (0.30)
3.0 (0.12)
1.2 (0.05)
RGE1100 17.5 (0.69) 26.0 (1.02)
5.1 (0.20)
7.6 (0.30)
3.0 (0.12)
1.2 (0.05)
New RGE1200 17.5 (0.69) 28.0 (1.10) 10.2 (0.40)
7.6 (0.30)
3.6 (0.14)
1.4 (0.06)
New RGE1400 27.9 (1.10) 27.9 (1.10) 10.2 (0.40)
7.6 (0.30)
3.4 (0.13)
1.4 (0.06)
* Kinked leads are
available for
RGE300 - RGE1400
Lead Size
RGE300–RGE1100
∅ 0.81
(0.032)
20 AWG
RGE1200–RGE1400
∅ 1.0
(0.040)
18 AWG
RGE300–RGE1400*
A
E
Marking
B
D
C
CL
CL
F
CL CL
Raychem Circuit Protection Devices
RGE Devices 133