English
Language : 

PGDS-50 Datasheet, PDF (5/12 Pages) –
Hi-Rel
PGDS-50 Series Grade
5- Electrical Specifications
Data are valid at +25°C, unless otherwise specified.
Parameter
Conditions
Limit or
typical
Units
PGDS-50-N-K
PGDS-50-O-K
Input
Compatible module
J series of DC/DC module 16-40Vdc
H series of DC/DC module 9-36Vdc
J series
H series
Under voltage lock- Turn-on voltage
Typical
VDC
out (UVLO)
Turn-off voltage
Typical
VDC
12
6
9
5,65
Start up time
Ui min. to max.
No load to full load
Maximum
ms
15
15
Permanent input
voltage range (Ui)
in normal operation
Full temperature range
Full load
Minimum
Maximum
VDC
VDC
17
12
37
37
Voltage drop-out
limit in low line
operation
Full temperature range
Minimum
MIL-STD-704A
AECMA EN2282
AIR2021E
DO160D cat A/B/Z
MIL-STD-1275A/B
VDC/s
10V/50ms
12V/30ms
12V/50ms
10V/15s
6V/1s
10V/15s
Compliant
Compliant
Compliant
Compliant
Not compliant
6V/1s
Compliant
Compliant
Compliant
Compliant
Compliant
Maximum
VDC/ms
80V/100ms
100V/50ms
Maximum
VDC/s
47V/1s
47V/1s
Voltage transient
limit in transient
Full temperature range
MIL-STD-704A
AECMA EN2282
80V/75ms
60V/50ms
Compliant
Compliant
Compliant
Compliant
operation
AIR2021E
60V/100ms
Compliant
Compliant
DO160D cat A/Z 80V/100ms
MIL-STD-1275A/B 100V/50ms
Compliant
Not compliant
Compliant
Compliant
4
Voltage spike
limit in transient
operation
50 Ohms impedance
50 Ohms impedance
50 Ohms impedance
50 Ohms impedance
15 mJ energy content
Current in inhibit
mode
Output
Output voltage
range
Ui min. to max.
Full load
Nominal voltage in
normal operation
Nominal voltage in In low line
low line operation Input voltage
Nominal voltage in
transient protection
mode
In transient
Input voltage
Efficiency
Ui = 28VDC
Full load
Maximum
MIL-STD-704A
AECMA EN2282
AIR2021E
DO160D cat A/Z
MIL-STD-1275A/B
VDC/µs
600V/10µs
400V/100µs
600V/10µs
600V/10µs
250V/70µs
Maximum
mA
Minimum
VDC
Maximum
VDC
Nominal
VDC
Nominal
VDC
Minimum
VDC
Nominal
VDC
Minimum
%
600V/20µs
Compliant
Compliant
Compliant
Compliant
/
25
600V/20µs
Compliant
Compliant
Compliant
Compliant
Compliant with
EMI front filter
25
16
40
Ui - 0,6
see page 6
figure 1
see page 6
figure 3
96
9
36
Ui - 0,6
see page 6
figure 2
see page 4
figure 4
96
Full temperature range Minimum
W
Output power range In low line operation Maximum
W
In transient operation Maximum
W
see page 6
figure 5
see page 6
figure 6
5
© Gaia Converter FC97-012.10/05 Revision H
For locations, phone, fax, E-Mail see back cover