English
Language : 

M74HC4852YRM13TR Datasheet, PDF (5/15 Pages) List of Unclassifed Manufacturers – Dual 4:1 channel analog MUX/DEMUX with injection current protection
M74HC4852
Absolute maximum ratings and operating conditions
Table 6.
DC specifications
Test condition
Value
Symbol Parameter VCC
(V)
TA = 25 °C
Up to 85 °C Up to 125 °C Unit
Min. Typ. Max. Min. Max. Min. Max.
2.0
1.5
1.5
1.5
3.0
VIHC
High level input
voltage
3.0
4.5
2.1
2.1
2.1
2.3
2.3
2.3
V
3.15
3.15
3.15
6.0
4.2
4.2
4.2
2.0
0.5
0.5
0.5
3.0
VILC
Low level input
voltage
3.3
4.5
0.9
0.9
1.0
1.0
1.35
1.35
0.9
1.0 V
1.35
6.0
1.8
1.8
1.8
2.0 IS = 2 mA
500 650
670
3.0
VIN = VIHC
215 280
320
RON ON resistance
3.3
4.5
or VILC
IS ≤ 2 mA
VIS = VCC to
GND
210 270
160 210
305
240
700
360
345 Ω
270
6.0
150 195
220
250
2.0 IS = 2 mA
4 10
15
ΔRON
Difference of
ON resistance
between
switches
3.0
VIN = VIHC
3.3
or VILC
4.5 IS ≤ 2 mA VIS = VCC/2
28
28
28
12
12
12
20
16
16 Ω
16
6.0
39
13
18
Input/output
IOFF
leakage current
(switch off) (any
6.0
channel)
Input/output
leakage current
IOFF (switch off)
6.0
(common
channel)
VIN = VCC or GND
±0.1
± 0.5
± 1.0 μA
± 0.2
±2
± 4 μA
Switch input
ION
leakage current
(switch on,
6.0
output open)
VIN = VCC or GND
±0.1
± 0.5
± 1 μA
Doc ID 8791 Rev 7
5/15