English
Language : 

AMC102 Datasheet, PDF (5/7 Pages) List of Unclassifed Manufacturers – Two-axis precision servo controller module
Electrical Characteristics
Parameter
Min.
Static
Supply Voltage
5.4
8
Supply current
Alarm relays switch rating
Dynamic
RS422 Baud rate
Maximum table size (tracking points)
3
Internal interpolation rate
0.02
Position feedback data rate
1
Amplifier drive voltage
0
Encoders
-
Humidity sensor output
0
Temperature sensor output
0
Maximum internal real-time timing error
Maximum accumulated timing error over
duration of
Real-time tracking error
Environmental
Temperature range - Operating
-40
- Storage
-55
Hunidity range - Operating
0
- Storage
0
Typ. Max. Unit
Condition / Note
10
V
40
V With optional switching regulator
180
mA Brake and alarm relays not active
340
mA Brake and alarm relays active
24
V
1.25
2
A
19.2
0.2
+0.01
1700
50
20
+10
16-bit
100
85
1
<1
+0.02
kbaud 28.8kb, 57.6kb may also be used
Hz Internally generated points
between table steps
Hz
V Output is differential +5V
SSI output format
% Factory-settable shutdown
threshold available
°C System shuts down @ +85°C
mS Defined as the synchronisation
error between sync pulse and
execution
mS Defined as the timing drift during a
typical 16min. satellite pass
see fig. 2
° Using 16-bit encoders. Degrades
with lower resolution encoder.
85
°C Factory set cut-out @ +85°C
+100 °C
90 %RH Non-condensing
100 %RH Non-condensing
AMC102-031111 Two-axis precision servo controller module
Page 5 of 7