English
Language : 

9171 Datasheet, PDF (5/6 Pages) List of Unclassifed Manufacturers – Single and dual output models with up to 210W output power
Programmable Dual-Range DC Power Supplies
9170 & 9180 series
Specifications
9171
9172
9173
9174
9181
9182
9183
9184
9185
Output Rating
Low Range
High Range
Number of Channels
Max Output Power
Line Regulation
Voltage
Current
Load Regulation1
Voltage
Current
0-10 V,
0-10 A
0-20 V,
0-5 A
1
100 W
0-35 V,
0-3 A
0-70 V,
0-1.5 A
1
105 W
0-10 V,
0-10 A
0-20 V,
0-5 A
2
200 W
0-35 V,
0-3 A
0-18 V,
0-8 A
0-10 V,
0-20 A
0-70 V,
0-1.5 A
0-36 V,
0-4 A
0-20 V,
0-10 A
2
1
1
210 W
144 W
200 W
≤ 0.01 %+1 mV
≤ 0.01 %+250 uA
≤ 0.01 %+1 mV
≤ 0.01 %+250 uA
0-35 V,
0-6 A
0-70 V,
0-3 A
1
210 W
0-100 V,
0-2 A
0-200 V,
0-1 A
1
200 W
0-400 V,
0-0.5 A
0-600 V,
0-0.35 A
1
210 W
Normal Mode ≤ 0.35 mVrms ≤ 0.5 mVrms / ≤ 0.35 mVrms ≤ 0.5 mVrms /
Voltage
/ ≤ 3 mVpp ≤ 5 mVpp / ≤ 3 mVpp ≤ 5 mVpp
≤ 0.35 mVrms /
≤ 3 mVpp
Ripple and Noise
(20 Hz – 20 MHz) Normal Mode
Current
≤ 2 mA rms
Common Mode
Current
≤ 1.5 uA rms
Programming /
Readback Resolution
Voltage
Current
1 mV
1 mA
2 mV
0.1 mA
1 mV
1 mA
2 mV
0.1 mA
1 mV
1 mA
≤ 0.5 mVrms ≤ 1.5 mVrms / ≤ 4.5 mVrms /
/≤5 mVpp ≤ 15 mVpp ≤ 45 mVpp
2 mV
0.2 mA
10 mV
0.1 mA
20 mV
0.01 mA
Programming /
Readback Accuracy
±(% output+offset)
Voltage
Current
≤ 0.05 %
+5 mV
≤ 0.1 %
+2 mA
≤ 0.05 %
+10 mV
≤ 0.1 %
+1 mA
≤ 0.05 %
+5 mV
≤ 0.1 %
+2 mA
≤ 0.05 %
+10 mV
≤ 0.1 %
+1 mA
≤ 0.05 %
+5 mV
≤ 0.1 %
+2 mA
≤ 0.1 %
+5 mA
≤ 0.05 %
+10 mV
≤ 0.1 %
+2 mA
≤ 0.05 %
+50 mV
≤ 0.1 %
+1 mA
≤ 0.05 %
+100 mV
≤ 0.1 %
+0.1 mA
Temperature
Coefficient per °C
±(% output+offset)
Voltage
Current
≤ 0.005 %+1 mV
≤ 0.01 %+3 mA
≤ 0.005 %
+10 mV
≤ 0.005 %
+20 mV
Transient Response Time2
Settling Time3
Measurement Time
OVP Accuracy
≤ 50 µs for output to recover to within 15 mV
≤ 0.5 %+0.1 V
≤ 30 ms
≤ 50 ms
≤ 100 µs for ≤ 100 µs for
output to
output to
recover to within recover to within
50 mV
120 mV
≤ 0.5 %+1 V
OCP Accuracy
OVP/OCP Response Time4
Rising Time at Full Load / No Load
≤ 8 ms
≤ 10 ms
≤ 8 ms
≤ 10 ms
≤ 0.5 %+0.1 A
≤ 1 ms
≤ 8 ms
≤ 10 ms
≤ 30 ms
≤ 40 ms
Falling Time at Full Load
≤ 8 ms
≤ 10 ms
≤ 8 ms
≤ 10 ms
≤ 8 ms
≤ 10 ms
≤ 30 ms
≤ 40 ms
Falling Time at No Load
Stability (8 hrs)
±(% output+offset)
Voltage
Current
≤ 250 ms
≤ 0.02 %+2 mV
0.1 %+1 mA
≤ 0.02 %
+10 mV
≤ 0.02 %
+20 mV
Notes:
1 With sense terminal connected.
2 Following a change in output current from full load to half load or vice versa.
3 Maximum time required for the output voltage to change from 1% to 99% or vice versa after receiving a VOLTage or VSET command via GPIB or USB interface.
4 Average time for output to start to drop after OVP/OCP condition occurs.
5
www.bkprecision.com