English
Language : 

LC1D18F7 Datasheet, PDF (49/252 Pages) List of Unclassifed Manufacturers – TeSys™ IEC-Style Contactors and Starters
TeSys™ K-line Mini-Contactors and Starters
Selection of Reversing Contactors for Motor Control
LC8K06105••
Sensitive-Environment Reversing Contactors for AC Control Circuits
The tables below show the kilowatt ratings (for international applications) and horsepower ratings (for
North American applications) for reversing contactors with mechanical interlock for use in sensitive
environments. They are recommended for use in areas sensitive to noise, high interference mains
supplies, and so forth. A coil with incorporated rectifier and suppressor is standard.
The contactors mount on 35 mm DIN rails or with 4 mm (# 6) screws. The wire termination screws are
in the open, “ready-to-tighten” position. Customer wiring is required to connect coil terminations to
electrical interlock; see page 60 (top row, center wiring diagram).
For information on add-on auxiliary contact blocks and accessories, see page 54 to 58.
Horsepower Ratings for North American Applications
Maximum Horsepower Rating
Category AC-3, 50/60 Hz
1-Phase
3-Phase
115/ 230/ 200/ 220/ 460/
120 V 240 V 208 V 240 V 480 V
575/
600 V
Max.
Inductive
Current
HP HP HP HP HP HP A
Kilowatt Ratings for International Applications
Standard power ratings of 3-phase
motors, 50/60 Hz in category AC-3
220 V
230 V
380 V
415 V
440/500 V
660/690 V
Rated
Operational
Current,
up to 440 V
Type of Connection
kW
kW
kW
A
Screw clamp q
0.5 1
1.5 1.5 3
3
6
1.5
2.2
3
6
Slip-on 1 x 0.25 in.,
or 2 x 0.11 in.
Solder pins for printed
circuit board
Screw clamp q
0.5 1.5 2
3
5
5
9
2.2
4
4
9
Slip-on 1 x 0.25 in.,
or 2 x 0.11 in.
Solder pins for printed
circuit board
Screw clamp q
0.5 1.5 3
3
7.5 10 12
3
5.5
4 (> 440)
5.5 (440)
12
p Use voltage codes on page 52 “Voltage Code Table” to complete catalog number.
q Pre-wired power circuit connections are standard on screw clamp versions.
Slip-on 1 x 0.25 in.,
or 2 x 0.11 in.
Solder pins for printed
circuit board
Auxiliary
Contacts
N.O.
1
–
1
–
1
–
1
–
1
–
1
–
1
–
1
–
1
–
N.C.
–
1
–
1
–
1
–
1
–
1
–
1
–
1
–
1
–
1
Catalog
Number
p
LC8K0610••
LC8K0601••
LC8K06107••
LC8K06017••
LC8K06105••
LC8K06015••
LC8K0910••
LC8K0901••
LC8K09107••
LC8K09017••
LC8K09105••
LC8K09015••
LC8K1210••
LC8K1201••
LC8K12107••
LC8K12017••
LC8K12105••
LC8K12015••
Weight
lb. (kg)
1.05 (0.480)
1.05 (0.480)
1.00 (0.460)
1.00 (0.460)
1.14 (0.520)
1.14 (0.520)
1.05 (0.480)
1.05 (0.480)
1.00 (0.460)
1.00 (0.460)
1.14 (0.520)
1.14 (0.520)
1.05 (0.480)
1.05 (0.480)
1.00 (0.460)
1.00 (0.460)
1.14 (0.520)
1.14 (0.520)
01/04
49
© 2001-2004 Schneider Electric All Rights Reserved