English
Language : 

V4-T1-6 Datasheet, PDF (4/98 Pages) List of Unclassifed Manufacturers – Miniature Circuit Breakers and Supplementary Protectors
1.1
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
Eaton’s QUICKLAG Industrial Circuit Breakers 1 Plug-In, Bolt-On, Cable-In/Cable-Out, continued
Continuous
Interrupting Ratings rms Symmetrical Amperes
1
Circuit
Breaker
Circuit
Breaker
Ampere
Rating
Number
of
Type
Type Code at 40°C
Poles
Vac
Vdc
Federal
Spec.
W-C-375b
Vac Ratings
120
120/240 240
Vdc Ratings 2
24–48 62.5 80
Page
Number
1
QCF
C
15–20
1, 2
120/240 24, 48, 62.5 —
22,000 —
—
3000 3000 —
V4-T1-27
QCF
C
1
QCR
C
15–30
10–60
2, 3
240
24, 48, 62.5 —
1, 2
120/240 24, 48, 62.5 —
—
10,000
—
10,000 10,000
—
3000 3000 —
3000 3000 —
V4-T1-27
V4-T1-27
1
QCR
C
QCR
C
1
QCHW
C
QCHW
C
1
QCHW
C
15–20
1, 2
120/240 24, 48, 62.5 —
15–30
2, 3
240
24, 48, 62.5 —
15–70
1
120/240 24, 48, 62.5 14a
15–100
2
120/240 24, 48, 80
14a
15–100
2, 3
240
—
14b
22,000
—
—
—
—
—
10,000
22,000
22,000
—
—
3000 3000 —
V4-T1-27
—
3000 3000 —
V4-T1-27
—
5000 3
—
V4-T1-22
—
5000 5000 5000 V4-T1-22
22,000 —
—
—
V4-T1-22
1
QHCX
QHCX
C
C
15–70
1
15–100
2
120/240 24, 48, 62.5 —
120/240 24, 48, 80
—
—
42,000
—
5000 3
—
V4-T1-22
—
42,000
—
5000 5000 5000 V4-T1-22
1
QHCX
C
QHCW
C
1
QHCW
C
QHCW
C
1
QCGFT
C, GF
15–100
3
15–30
1
15–30
2
15–20
3
15–40
1
240
—
—
120/240 24, 48, 62.5 15a
120/240 24, 48, 80
15a
240
—
15b
120
—
—
—
—
—
—
10,000
—
65,000
65,000
—
—
42,000 —
—
—
V4-T1-22
—
5000 3
—
V4-T1-22
—
5000 5000 5000 V4-T1-22
65,000 —
—
—
V4-T1-22
—
—
—
—
V4-T1-29
1
QCGFT
C, GF
15–50
2
120/240 —
—
QCHGFT
C, GF
15–30
1
120
—
—
—
10,000
—
22,000 —
—
—
—
—
V4-T1-29
—
—
—
V4-T1-29
1
QCHGFT
C, GF
15–30
2
120/240 —
—
QCGFEP
C, GFEP
15–40
1
120
—
—
1
QCGFEP
C, GFEP
15–50
2
120/240 —
—
—
22,000
—
10,000 —
—
—
10,000
—
—
—
—
V4-T1-29
—
—
—
V4-T1-29
—
—
—
V4-T1-29
QCHGFEP C, GFEP
15–30
1
120
—
—
1
QCHGFEP C, GFEP
15–30
2
120/240 —
—
22,000 —
—
—
22,000
—
—
—
—
V4-T1-29
—
—
—
V4-T1-29
1
Notes
1 QUICKLAG circuit breakers are suitable for application in relative humidity 0–95% noncondensing.
1
2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed.
3 62.5 Vac interrupting rating is 3800 AIC 10–50A and 2500 AIC 55–100A continuous.
1
Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA.
For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T1-31 to V4-T1-36.
1
1
1
1
1
1
1
1
1
1
1
1
V4-T1-4