English
Language : 

RWS-F916 Datasheet, PDF (4/7 Pages) List of Unclassifed Manufacturers – Wireless Hi Sensitivity Receiver Module
Electrical Characteristic, 115.2 Kbps Amplitude-Shift Keyed,
High-Sensitivity RX Mode
Characteristic
Sym Note Min Type Max Unit
Operating Frequency
fo 913.80
914.20 MHz
Modulation Type
OOK
Data Rate
2.4
Kbps
Receiver
IR
Performance (OOK
@ 2.4 kbps) Input
Current, 3 Vdc Supply
Input Signal for 10
BER, 25 C
Rejection, 30 MHz
Sleep to Receive
Switch Time (100
RREJ
mssleep, -85 dBm
signal)
tSR
3
1.8
mA
1
+98 dBm
55
dB
200
us
Sleep Mode Current
IS
5
uA
Power Supply
Voltage Range
Vcc
2.7
3.5
Vdc
Operating Ambient
Temperature
TA
-10
+70
℃
Receiver Set-Up, 3.0 Vdc, -10 to +70
Item
Symbol OOK OOK
Nominal NRZ Data DRNO
Rate
M
2.4
19.2
Minimum Signal
Pulse
SPMIN 416.67 52.08
Maximum Signal
Pulse
SPMAX 1666.68 208.32
http://www.wenshing.com.tw ; http://www.rf.net.tw
ASK
115.2
8.68
34.72
Unit Note
Kbps
us
us
see
pages 1
&2
single
bit
4 bits of
same
value
RWS-F916 Datasheet P.4