English
Language : 

MLV0603ES005V0100NT Datasheet, PDF (4/6 Pages) List of Unclassifed Manufacturers – Surface Mount Multilayer Varistors
Surface Mount Multilayer Varistors
Rev. Aug.11
Environmental Tests
No.
Test
1
Soldering heat
resistance
2 Solderability
Requirement
Test condition
BDV change ” f10 %
No mechanical damage
One dip at 260ºC for 5 sec.
One dip at 255ºC for 5 sec.
New solder coverage • 80 % Non-active flux
Test reference
MIL-STD-202
Method 210
IEC 60068-2-20
MIL-STD-202
Method 208
IEC 60068-2-20
3
Maximum
current
surge BDV change ” f10 %
No mechanical damage
100 pulses of 8/20 ȝs with
maximum surge current and 30 sec.
interval at 25ºC and 30~65 % RH
CECC 42000
IEC 1051-1 Test 4.5
4
Maximum
energy
surge BDV change ” f10 %
No mechanical damage
100 pulses of 10/1000 ȝs with
maximum surge current and 90 sec. CECC 42000
interval at 25ºC and 30~65 % RH
5 Thermal cycling
BDV change ” f10 %
No mechanical damage
Leakage current ” 200 ȝA
5 cycles between -40嘙C and 125ºC
with 30 min. dwell time at the
CECC 42000
temperature extremes and 60 min. IEC 60068-2-14
dwell time at 25嘙C 
6
Low temperature BDV change ” f10 %
resistance
No mechanical damage
Leakage current ” 200 ȝA
1000 hr at -50嘙C 
IEC 60068-2-1
7
Low temperature BDV change ” f10 %
load resistance No mechanical damage
Leakage current ” 200 ȝA
1000 hr at -50嘙C with working
voltage applied
IEC 60068-2-1
8
High temperature BDV change ” f10 %
resistance
No mechanical damage
Leakage current ” 200 ȝA
1000 hr at 150嘙C 
MIL-STD-202
Method 108
CECC 42000
9
High temperature BDV change ” f10 %
load resistance No mechanical damage
Leakage current ” 200 ȝA
10
Humidity
resistance
BDV change ” f10 %
No mechanical damage
Leakage current ” 200 ȝA
11
Humidity
load resistance
BDV change ” f10%
No mechanical damage
Leakage current ” 200 ȝA
1000 hr at 85嘙C with working
voltage applied
CECC 42000
MIL-STD-202
500 hr at 40嘙C and 90 ~ 95 % RH
Method 103
IEC 60068-2-3
CECC 42000;
MIL-STD-202
500 hr at 40°C and 90 ~ 95 % RH Method 103
with working voltage applied
IEC 60068-2-3
CECC 42000
12 ESD contact test*
Varistor voltage change
>115 % working voltage
Contact electrostatic discharge 100
times with 1 second intervals at 8 KV
(Level 4 ) and polarity: +,-
IEC 61000-4-2
13 ESD air test*
Varistor voltage change
>115 % working voltage
Air contact electrostatic discharge 100
times with 1 second intervals at 15
KV (Level 4 ) and polarity:+,-
IEC 61000-4-2
For ES series only.

Website: www.aemchina.com & www.aemcomponents.com