Example:
BAROMETER MODULE
HP01-JK
Version2.3
D1(P0)=30000
D2(P0)=4100
TCS=-0.55
SNS=27
(obtained after power up reading: D1)
(obtained after power up reading: D2)
(nominal module value from this data sheet)
(nominal module value from this data sheet)
D1=30036
D2=4107
(current pressure AD reading from module)
(current temperature AD reading from module)
dUT = 4107-4100 = 7
dTCS=-0.55*7=-3.85
dUP=30036+3.85-30000=39
P2=39/27=1.44
P=1013.2+1.44=1014.6
Serial Interface
The I2C interface is used for reading measurement result from AD conversion:D1 and D2.
Reading Temperature and Pressure value:D1,D2
AD chip I2C address is set to 0xEE (device write address), 0xEF (device read
address). In order to get the AD value D1 and D2, you have to follow the following
timing sequence:
Pressure Measure:
S 11101110 A 11111111 A 11110000 A P D S 11101110 A 11111101 A S 11101111 A MSB A LSB N P
Select pressure measurement
Read AD value back
Temperature Measure:
S 11101110 A 11111111 A 11101000 A P D S 11101110 A 11111101 A S 11101111 A MSB A LSB N P
Select temperature measurement
Read AD value back
S: I2C bus START (refer to AT24C02 EEPROM start command)
P: I2C bus STOP (refer to AT24C02 EEPROM stop command)
4