English
Language : 

HDPM01 Datasheet, PDF (4/19 Pages) List of Unclassifed Manufacturers – Integrated pressure sensor
HDPM01
4. Recommended Operating Conditions
4.1 Recommended Operating Conditions of pressure
Parameter
Supply Voltage
Supply Current
during conversion
Stand by
Operating Pressure Range
Symbol Conditions
VDD
I
VDD=3V
P
Operating Temperature Range
T
MCLK
T
Duty Cycle of MCLK
Serial Date Rate
SCL
HDPM01
Min
2.4
300
-20
TBD
30
40%
Typ
3
500
2
25
32768
50%
Max
3.6
1100
60
60
35
60%
400
Unit
V
V
  
  
hpa (abs)
°C
°C
KHz
%
KHz
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http://www.hoperf.com
4