English
Language : 

D04072080G-00 Datasheet, PDF (4/14 Pages) List of Unclassifed Manufacturers – SPECIFICATION FOR APPROVAL
3. PERFORMANCE CHARACTERISTIC
RATED SPEED
AIR FLOW
STATIC PRESSURE
ACOUSTIC NOISE
AIR FLOW V.S. PRESSURE
INSULATION CLASS
INSULATION RESISTANCE
PLASTIC HOUSING
DIELECTRIC STRENGTH
4700 RPM ± 15% at rated voltage
5.5 CFM
0.08 Inch-H2O
12.8 dB(A)
See Page 5
UL Class A
500M ohm at 500 VDC between internal stator and
lead wire (+)
Applied AC 500 V for one minute or AC 600 V for 2
Seconds between housing and lead wire (+)
LIFE EXPECTANCY
PROTECTION
60,000 Hours at 40 deg. C, 65% humidity, 90% CL.
Automatic Restart
Note: In a situation where the fan is locked by an external
force while the electricity is on, an increase in coil
temperature will be prevented by temporarily turning off
the electrical power to the motor. The fan will automatically
restart when the locked rotor condition is released.
Polarity Protection
4. SAFETY
SAFETY
UL
CUR
TUV
CE
NO.
E77551
E77551


建準電機
SUNONWEALTH
Page 4 of 14
2012.07.23