Language : 

EP1C12F256I7N Datasheet, PDF (345/385 Pages) List of Unclassifed Manufacturers – Cyclone Device Handbook, Volume 1
Serial Configuration Devices (EPCS1, EPCS4, EPCS16, EPCS64, and EPCS128) Data Sheet
f
Refer to the configuration chapter in the appropriate device handbook
for more information about configuring the FPGAs in AS mode or other
configuration modes.
Multiple devices can be configured by a single EPCS device. However,
serial configuration devices cannot be cascaded. Refer to Table 14–1 to
ensure the programming file size of the cascaded FPGAs does not exceed
the capacity of a serial configuration device. Figure 14–4 shows the AS
configuration scheme with multiple FPGAs in the chain. The first FPGA
is the configuration master and has its MSEL[] pins set to AS mode. The
following FPGAs are configuration slave devices and have their MSEL[]
pins set to PS mode.
Figure 14–4. Multiple Devices in AS Mode Note (5)
VCC (1)
VCC (1)
VCC (1)
10 k9
10 k9
10 k9
Serial
Configuration
Device (2)
DATA
DCLK
nCS
ASDI
Cyclone FPGA (Master)
CONF_DONE
nSTATUS
nCONFIG
nCE
DATA0
DCLK
nCSO
ASDO
nCEO
MSEL[1..0] 00 (3)
Cyclone FPGA (Slave)
CONF_DONE
nSTATUS
nCONFIG
nCE
DATA0
DCLK
nCEO
N.C.
MSEL[1..0] 01 (4)
Notes to Figure 14–4:
(1) VCC = 3.3 V.
(2) Serial configuration devices cannot be cascaded.
(3) Connect the FPGA MSEL[] input pins to select the AS configuration mode. For details, refer to the appropriate
FPGA family chapter in the Configuration Handbook.
(4) Connect the FPGA MSEL[] input pins to select the PS configuration mode. For details, refer to the appropriate
FPGA family chapter in the Configuration Handbook.
(5) For more information about configuration pin I/O requirements in an AS scheme for a Cyclone III FPGA, refer to
the Configuring Cyclone III Devices chapter in volume 1 of the Cyclone III Device Handbook.
Altera Corporation
May 2008
14–11
Cyclone Handbook, Volume 1