TABLE I. Electrical performance characteristics - Continued.
1/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in
output voltage due to heating effects are covered under the specification for thermal regulation. With exception of
cases U, 2, and 4, all output measurements are referenced to the case. Measurements taken at the output lead must be
adjusted for lead resistance.
2/ If not tested, shall be guaranteed to the specified limits in table herein.
3/ To determine the line regulation limits for 3.0 V < VDIFF < 60 V (or 3.3 V ≤ VDIFF ≤ 60 V) add the limits for
3.0 V < VDIFF < 40 V (or 3.3 V ≤ VDIFF ≤ 40 V) to the limits for 40 V < VDIFF < 60 V.
4/ Device types 02 and 07 with case outline U supplied to this drawing have been characterized through all levels M, D, P, L,
and R of irradiation. However, these devices are only tested at the ‘R’ level. Pre and post irradiation values are identical
unless otherwise specified in table I. When performing post irradiation electrical measurements for any RHA level,
TA = +25°C.
5/ These parts may be dose rate sensitive in a space environment and demonstrate enhanced low dose rate effect.
Radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883,
method 1019 condition A.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
X
77034
SHEET
29