English
Language : 

ML9286-03 Datasheet, PDF (27/37 Pages) List of Unclassifed Manufacturers – Vacuum fluorescent display tube controller driver
FEDL9286-03
ML9286-xx
6. Number of timing set
(Writes the number of display timing to the display timing register.)
The number of timing set can T9 to T24 display timing using 4-bit data.
When the RESET signal is input, the number of timing register value is "0". (see “Reset Function”) Always
execute this instruction to change the number of timings before turning the display on.
[Command format]
1st byte
LSB
MSB
B0 B1 B2 B3 B4 B5 B6 B7
K0 K1 K2 K3 * 0 1 1 : selects the number of timing set mode
K0 (LSB) to K3 (MSB) : number of timing data (4 bits)
*
: Don't care
[Relation between setup data and timing set]
HEX K0 K1 K2 K3
0
0000
1
1000
2
0100
3
1100
4
0010
5
1010
6
0110
7
1110
Timing Setting
T1 to T24
T1 to T9
T1 to T10
T1 to T11
T1 to T12
T1 to T13
T1 to T14
T1 to T15
* The state when RESET signal is input.
HEX K0 K1 K2 K3
8
0001
9
1001
A
0101
B
1101
C
0011
D
1011
E
0111
F
1111
Timing Setting
T1 to T16
T1 to T17
T1 to T18
T1 to T19
T1 to T20
T1 to T21
T1 to T22
T1 to T23
27/37