English
Language : 

S-8204BAD Datasheet, PDF (24/36 Pages) List of Unclassifed Manufacturers – BATTERY PROTECTION IC FOR 3-SERIES OR 4-SERIES CELL PACK
BATTERY PROTECTION IC FOR 3-SERIES OR 4-SERIES CELL PACK
S-8204B Series
Rev.3.6_00
Table 10 Constants for External Components (Circuit in Figure 11)
Symbol
RVC1*1
RVC2*1
RVC3*1
RVC4*1
RDOP
RCOP
RVMP
RCTLC
RCTLD
RVINI
RSEL
RVDD*1
CVC1*1
CVC2*1
CVC3*1
CVC4*1
CCCT
CCDT
CVDD*1
CCIT
RSENSE
M1
M2
ZD1
REB−
RATL
Nch FET1
Nch FET2
Min.
0.51
0.51
0.51
0.51
2
0.1
1
1
1
1
1
22
0
0
0
0
0.01
0.01
0
−
−
−
−
−
−
−
−
−
Typ.
1
1
1
1
5.1
1
5.1
1
1
1
1
47
47
47
47
47
0.1
0.1
1
0.1
−
−
−
−
1
20
−
−
Max.
Unit
1
kΩ
1
kΩ
1
kΩ
1
kΩ
10
kΩ
1
MΩ
10
kΩ
10
kΩ
10
kΩ
10
kΩ
100
kΩ
100
Ω
100
nF
100
nF
100
nF
100
nF
−
μF
−
μF
2.2
μF
−
μF
−
−
−
−
−
−
−
−
−
MΩ
−
MΩ
−
−
−
−
*1. Set up a filter constant to be RVDD × CVDD = 47 μF • Ω or more, and to be RVC1 × CVC1 = RVC2 × CVC2 =
RVC3 × CVC3 = RVC4 × CVC4 = RVDD × CVDD.
Caution 1. The above constants may be changed without notice.
2. It is recommended that filter constants between the VDD pin and the VSS pin should be set to
approximately 47 μF • Ω.
e.g., CVDD × RVDD = 1.0 μF × 47 Ω = 47 μF • Ω
Sufficient evaluation of transient power supply fluctuation and overcurrent protection function with
the actual application is needed to determine the proper constants. Contact our sales office in case
the constants should be set to other than 47 μF • Ω.
3. It has not been confirmed whether the operation is normal in circuits other than the above example
of connection. In addition, the example of connection shown above and the constants do not
guarantee proper operation. Perform thorough evaluation using an actual application to set the
constant.
24